Notifications
You must be signed in to change notification settings - Fork 916
/
nas-pd03z.xml
118 lines (104 loc) · 7.33 KB
/
nas-pd03z.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="2">
<MetaData>
<!--
Neo (Coolcam) NAS-PD03Z Motion Sensor (PIR) Version 2
No official manual available
Does not figure on https://products.z-wavealliance.org
-->
<MetaDataItem name="Name">Neo (Coolcam) NAS-PD03Z Motion Sensor (PIR) Version 2</MetaDataItem>
<MetaDataItem name="ProductPage">https://www.szneo.com/en/products/show.php?id=197</MetaDataItem>
<MetaDataItem name="ProductPic">images/shenzen_neo/nas-pd02z.png</MetaDataItem>
<MetaDataItem name="WakeupDescription">Press button in sensor once. If successfull, LED will blink one time.</MetaDataItem>
<MetaDataItem name="InclusionDescription">Set gateway in inclusion mode. Press button in sensor three times. LED will flash red five times and then on and off alternately.</MetaDataItem>
<MetaDataItem name="ExclusionDescription">Set gateway in exclusion mode. Press button in sensor three times. LED will flash red five times and then on and off alternately.</MetaDataItem>
<MetaDataItem name="ResetDescription">Press and hold button the button in sensor for 10-15 seconds. LED will one time first and then five times on and off alternately. Release button.</MetaDataItem>
<ChangeLog>
<Entry author="Mick Venhorst" date="19 September 2020" revision="1">Initial version, based on PD02Z file</Entry>
<Entry author="Mick Venhorst" date="23 November 2020" revision="2">Changed value type list to byte for index 1, value of index 4 ws not present in list values </Entry>
</ChangeLog>
</MetaData>
<!-- Configuration Parameters -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Motion detection sensitivity" value="12" min="8" max="255" size="1">
<Help>Adapt the sensitivity of the motion detection where 8 means highest sensibility and 255 lowest.</Help>
</Value>
<Value type="short" genre="config" instance="1" index="2" label="Motion detection ON time" units="second" value="30" min="5" max="600" size="2">
<Help>This parameter can be determined how long the associated devices should stay ON status.
For instance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command to an associated device with value basic set level if PIR detector is triggered and the associated device will be turned on 30(second) before it is turned off.
This Parameter value must be large than Parameter 6# - Retrigger interval.
Available Settings:5 to 600(second).
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Basic Set Level" value="255" min="0" max="255" size="1">
<Help>Basic Set Command will be sent, on the associated devices (group 2), where contains a value when PIR detector is triggered, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
This Parameter is used to some associated devices.
Available Settings: 0, 1 to 99 or 255.
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="4" label="Motion detection function" min="0" max="255" value="255" size="1">
<Help>
Enable the motion detection (PIR) function.
This parameter does not effect the luminance reporting.
</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="255" />
</Value>
<Value type="short" genre="config" instance="1" index="5" label="Ambient Illumination Lux Level" units="lux" value="100" min="0" max="1000" size="2">
<Help>
Define the illumination level value which determines when the 'Illumination switch ON function' is activated.
If the illumination level falls below this value and a person moves across or within the detected area, the motion sensor will switch on the associated device (group 2).
0 to 1000(Lux).
</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="6" label="Retrigger interval " units="second" value="8" min="1" max="8" size="1">
<Help>
Period after motion detection in which the sensor is insensitive for new motion detection.
This value must be less than the 'Motion detection ON time'.
Available Settings: 1 to 8(s).
</Help>
</Value>
<Value type="short" genre="config" instance="1" index="7" label="Illumination reporting interval" units="second" value="180" min="60" max="36000" size="2">
<Help>
Determine the time between illumination reports, even when value has not changed.
NOTE: This Value Must Be less than Wakeup Interval Time.
Available Settings: 60 ~ 36000(second).
</Help>
</Value>
<Value type="list" genre="config" instance="1" index="8" label="Illumination function" value="0" min="0" max="1" size="1">
<Help>
Enable the function to switch on a associated device (group 2) once motion has been detected and the illumination level will be less than the value specified in 'Illumination switch ON level'.
</Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="1" />
</Value>
<Value type="byte" genre="config" instance="1" index="9" label="Illumination report threshold" units="lux" value="100" min="0" max="100" size="1">
<Help>This parameter defines by how much Lux Level must change, in lux, to be reported to the main controller.</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="10" label="Ambient Temperature Differential Level Report" units="0.1 C" value="5" min="0" max="127" size="1">
<Help>This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured temperature value to nodes associated in lifeline.</Help>
</Value>
<Value type="list" genre="config" instance="1" index="11" label="Led Blink Enable" value="1" min="0" max="1" size="1">
<Help>This parameter can enabled or disable the PIR led blinking function. </Help>
<Item label="Disable" value="0" />
<Item label="Enable" value="1" />
</Value>
<Value type="list" genre="config" instance="1" index="12" label="Motion Event Report One Time Enable (temperature reporting version)" value="1" min="0" max="1" size="1">
<Help>The motion detected event can be sent multiple times/only once until device report motion cleared event. </Help>
<Item label="multiple times" value="0" />
<Item label="only once" value="1" />
</Value>
<Value type="short" genre="config" instance="1" index="99" label="Ambient Light Intensity Calibration" value="1000" min="1" max="65535" size="2">
<Help>This parameter defines the calibrated scale for ambient light intensity.</Help>
</Value>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="4">
<Group index="1" max_associations="4" label="Lifeline" />
<Group index="2" max_associations="4" label="Control Commands BASIC_SET" />
<Group index="3" max_associations="4" label="Send Notification Report" />
<Group index="4" max_associations="4" label="Send Sensor Binary Report" />
</Associations>
</CommandClass>