Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

QMCPACK does not abort when XML includes are misssing #1423

Closed
prckent opened this issue Mar 6, 2019 · 0 comments
Closed

QMCPACK does not abort when XML includes are misssing #1423

prckent opened this issue Mar 6, 2019 · 0 comments
Assignees

Comments

@prckent
Copy link
Contributor

prckent commented Mar 6, 2019

Running the oxygen atom lab 2, with unmodified example input, should generate an abort. Instead a SEGV occurs. The "I/O warning" should abort but does not.

pwd
/home/ ... /qmcpack/labs/lab2_qmc_basics/oxygen_atom
../../../../build_intel2018/bin/qmcpack O.q0.opt.in.xml

Random Number
 -------------
  Offset for the random number seeds based on time: 20

  Range of prime numbers to use as seeds over processors and threads = 79-199

I/O warning : failed to load external entity "PTCL_XML"
ERROR File PTCL_XML is invalid
ERROR ERROR: No target particle e exists.
I/O warning : failed to load external entity "���"
ERROR File ��� is invalid
Segmentation fault
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment