Skip to content

Commit

Permalink
first draft of the conventional activated sludge system
Browse files Browse the repository at this point in the history
  • Loading branch information
yalinli2 committed Jan 19, 2022
1 parent b4eb727 commit 8b96dae
Showing 1 changed file with 37 additions and 28 deletions.
65 changes: 37 additions & 28 deletions exposan/activated_sludge/system.py
Original file line number Diff line number Diff line change
Expand Up @@ -10,9 +10,10 @@
for license details.
'''

from flexsolve import IQ_interpolation
from qsdsan import Component, Components, WasteStream, set_thermo, System
from qsdsan.sanunits import Screening, ActivatedSludgeProcess, \
BeltThickener, SludgeDigester, CHP
from qsdsan.sanunits import Screening, Mixer, ActivatedSludgeProcess, \
BeltThickener, SludgeDigester, CHP as CHPunit

__all__ = ('cmps',)

Expand Down Expand Up @@ -52,30 +53,38 @@
units=('mgd', 'mg/L'))


U1 = Screening('U1', ins=inf)
U2 = ActivatedSludgeProcess('U2', ins=(U1-0, 'air'),
outs=('eff', 'sludge', 'emission'))
U3 = BeltThickener('U3', ins=U2-1, outs=())



cas = System('cas', path=(U1, U2, U3))
cas.simulate()
'''
System should have the following units:
Screening
ActivatedSludgeProcess (aeration tanks & clarifiers)
Sludge handling units (at least GBT, maybe also others):
X_thickened_WAS = 25000; %[mg/L]
CHP
'''

# @property
# def active_biomass(self):
# '''[tuple] IDs of active biomass (particulate & organic & degradable) components.'''
# return self.get_IDs_from_array(self.x*self.b*self.org)
# =============================================================================
# Units and the system
# =============================================================================

# @property
# def inert_biomass(self):
# '''[tuple] IDs of inert biomass (particulate & organic & undegradable) components.'''
# return self.get_IDs_from_array(self.x*self.org-self.x*self.b*self.org)
U1 = Screening('U1', ins=inf)
M1 = Mixer('M1', ins=(U1-0, ''))
ASP = ActivatedSludgeProcess('ASP', ins=(M1-0, 'ASP_air'),
outs=('treated', 'was', 'offgas'))
GBT = BeltThickener('GBT', ins=ASP-1, outs=(1-M1, 'thickened'))
thickened = GBT.outs[1]
# Update the biomass concentration to be at the set value
# There will be a warning when solving it, due to the unrealistic
# sludge moisture content (i.e., it exceeds in the moisture content of the feeds)
# but it is fine since that's only testing the bound
def X_inert_at_mc(mc):
GBT.sludge_moisture = mc
GBT._set_split_at_mc()
return thickened.iconc['X_inert']-25000
def GBT_spec():
lb = 1e-3
mixed_F_mass = GBT._mixed.F_mass
if mixed_F_mass == 0:
ub = 1-1e-3
else:
ub = max(lb+1e-3, GBT._mixed.imass['Water']/mixed_F_mass)
IQ_interpolation(f=X_inert_at_mc, x0=lb, x1=ub, xtol=1e-3, ytol=1,
checkbounds=False)
GBT.specification = GBT_spec

AD = SludgeDigester('AD', ins=GBT-1, outs=('disposed', 'biogas'))

CHP = CHPunit('CHP', ins=(AD-1, 'natural_gas', 'CHP_air'), outs=('emission', 'solids'))

cas = System('cas', path=(U1, M1, ASP, GBT, AD, CHP))
cas.simulate()

0 comments on commit 8b96dae