package of XXSim
- How to start
There is a software operation video in the HOW-TO-START directory. Through this video, you will know how to run the XXSim model directly, and how to convert the Eclipse model into XXSim model and run it ( the conversion of CMG model is similar to the operation of Eclipse model ).
- Update history
2019/09/12 Release XXGraph which can read and view summary vectors of XXSim and Eclipse.
2019/07/08 Fixed some bugs.
2018/05/31 GUI New Features of v1.5
The most important update is the release of a bata version of CMG to XXSim converter with following basic features:
-
the standard black oil model (IMEX);
-
the standard compositional model(GEM);
-
the standard thermal model(STARS);
-
improved 3DView module;
-
more adjustments and optimizations of Eclipse to XXSIM converter;
-
fixed the bug of the model directory that can not take the space character.
XXSIM New Features:,
-
added multiple pvt tables for black oil;
-
added multiple equilibration regions;
-
added multiple viscosity tables for thermal;
-
added historical rates and wbhp of each well for history match purpose;
-
added Restart option.
2018/01/02 New for v1.1.1
- Added the conversion of Eclipse keyword SWATINIT;
- Fixed some bugs;
2017/12/12 New for v1.1
New features of XXSim and Eclipse to XXSim converter:
-
Added DUALPORO module in XXSim and conversions of keywords for dual poro model: DUALPORO, GRAVDR, DUPNUM, DZMATRIX, MULTMF.
-
Added conversions of Well Group constraints.
-
Added conversion of keywords related to faults;
-
Improved the conversion of BOX, MULTIPLY, ADD, EQUALS, MINVALUE, MAXVALUE, so that all the legal arrays could be converted properly now.
-
Added conversions of keywords: MULTIREG, MULTREGT, MULTREGH;
-
Added conversion of keyword WPIMULT.
-
Thermal model conversion.
-
Add _xx to the converted eclipse data file.
-
Output region and group rates and cumulative in smspec and unsmry files.
-
And fixed some bugs.