Skip to content

SJTU-DDST/nvds

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

NVDS

Fast replication over RDMA fabric for NVM-based storage system.

DEPENDENCY

BUILD

  • Get the source code:
$ git clone https://github.com/wgtdkp/nvds --recursive
  • Checkout the master branch of submodule json:
$ cd nvds/json && git checkout master
  • Build nvds from source:
$ cd ../src && make all

INSTALL

$ make install # root required

RUN

Navigate to directory script:

script$ ./startup.sh

CONFIGURE

cluster

Parameters below are defined in header file common.h, recompilation and reinstallation are needed for changes to take effect.

parameter default range description
kNumReplicas 1 [1, ] the number of replications in primary backup
kNumServers 2 [1, ] the number of servers in this cluster
kNumTabletsPerServer 1 [1, 16] the number of tablets per server

The volume of the whole cluster equals to: kNumServers * kNumTabletsPerServer * 64MB;

servers

Specify server addresses in file script/servers.txt. The total number of servers should equals to parameter kNumServers. The file format: a line for a server address(ip address and port number separated by space). An example of two servers:

192.168.99.14 5050
192.168.99.14 5051

PROGRAMMING

To connect to a nvds cluster, a client only needs to include header file nvds/client.h and link nvds's static library. A tutorial snippet below shows how to put a key/value pair to the cluster and fetch it later:

#include "nvds/client.h"

#include <iostream>
#include <string>

int main() {
  try {
    nvds::Client c {"192.168.99.14"};
    c.Put("hello", "world");
    std::cout << "hello: " << c.Get("hello") << std::endl;
  } catch (boost::system::system_error& e) {
    NVDS_ERR(e.what());
  } catch (nvds::TransportException& e) {
    NVDS_ERR(e.msg().c_str());
    NVDS_LOG("initialize infiniband devices failed");
  }
  return 0;
}

Compile:

g++ -std=c++11 -Wall test_client.cc -lnvds -lboost_system -lboost_thread -pthread -libverbs

The whole code can be obtained in source file src/test_client.cc.

TROUBLESHOOTING

enable UD

If ibv_create_ah failed with "Cannot allocate memory", first, checkout the infiniband port status by typing command ibstatus; it should show that the port state is INIT; it's caused by disabling of opensm, start opensm by command: /etc/init.d/opensmd start; make sure the port state transformed to ACTIVE. It should be fixed then. This problem usually occurs after reboot, just enable opensm once started.

setting up IPoIB

Setting up IPoIB for testing of memcached latency. Do below steps on both client and server machine.

  1. lsmod | grep ib_ipoib check if ipoib module is listed. If not, modprobe ib_ipoib;
  2. ifconfig ib0 10.0.0.7/24 setting route and address (the address is for ddst7, you may specify an address as you like) of ib0;
  3. make sure opensm service is enabled, you can restart it by service opensmd restart;
  4. ping 10.0.0.4 ping peer machine (this address must be 10.0.0.*) to make sure IPoIB works for you.

Have fun then!

About