The file sctructure of the ddck files is shown in the example.ddck file in the pytrnsys_ddck repository root. Each ddck should contain the following parts. Some parts can be empty if not used.

Local and global variables

Pytrnsys knows two kinds of variables. Consider:

EQUATIONS 1
heatingOn = LT($Tamb, 15)

Here, heatingOn is a "local" variable, i.e., it can only be accessed from within the current ddck but not from other ddcks. $Tamb, on the other hand, is a "global" variable: it can be accessed from any ddck. You can also define your own global variables; just prefix them with a dollar sign like so: $myGlobalVariable.

If you really need to access a local variable from outside its ddck (e.g. to change a solar collector's area from the run.config) you need to prefix the variable with the component's name. I.e., if your collector is called Coll and its area is called A locally, you can access the variable from outside by the name CollA.

Header

In the header the name of the ddck as well as a contact person, the creation date and some information about the last changes are specified. In addition, there is a section for a general description of the ddck:

*******************************
**BEGIN example.ddck
*******************************

*****************************************
** Contact person : author
** Creation date  : date
** Last changes   : date, name
*****************************************

***************************************************************************
** Description:
** Overall description of the ddck file
** TODO: Any improvements needed
***************************************************************************

Inputs from hydraulic solver

The main inputs to a particular component/ddck are the input mass flow rates and the input temperatures for each input port. There is a special syntax to access these values. To access the input temperature and mass flow rates at the condenser and evaporator inlet (called Cond and Evap, respectively, in this example) within a heat pump ddck file, e.g., do the following:

***********************************
** inputs from hydraulic solver
***********************************

TCondIn = @temp(CondIn) ! Condenser input temperature
MCond = @mfr(CondIn)  ! Condenser mass flow rate

TEvapIn = @temp(EvapIn) ! Evaporator input temperature
MEvap = @mfr(EvapIn)  ! Evaporator mass flow rate

Besides temperature (@temp) and mass flow rate (@mfr) you can also access the heat capacity (@cp) and the density (@rho) of the fluid circulating through a given port in the same way as shown above.

Outputs to the hydraulic solver

The main outputs of a component/ddck are the temperatures at its output ports. These can be specified as follows (again using the heat pump example [see above]):

***********************************
** outputs to hydraulic solver
***********************************

@temp(CondOut) = [20,2]
@temp(EvapOut) = [20,4]

Here, 20 would be the unit number of your heat pump type and 2 and 4 the type's outputs corresponding to the condenser and evaporator output temperatures.

Outputs to the energy balance

Pytrnsys can automatically compute an energy balance of your system. In order to do that it needs to be told what should go into the energy balance. You can tell pytrnsys about your component/ddck's contribution to the energy balance like so:

******************************************************************************************
** outputs to energy balance in kWh and ABSOLUTE value
******************************************************************************************

@energy(heat, in, cond) = [20, 6]   ! heat going into the system and out of our HP component
@energy(heat, out, evap) = [20, 8]  ! heat going out of the system and into our HP component

The in and out are from the system's perspective: out would be out of the system and into a storage, e.g. (i.e. when the storage is charged @energy(heat, out, ...) would be positive).

Dependencies with other ddck files

In order to enhance modularization, dependencies with other ddcks should be kept minimal. Dependencies that cannot be avoided and are neither part of the component-database relation or the general variables should be declarated and reassigned to an internally used variable in this part:

***********************************
** Dependencies with other ddck
***********************************

** Re-assing here the variables necessary from other types
** variableInternal = variableExternal
** Exception: those from general variables

Outputs to other ddck files

Variables that are designated to be used in other ddck files should be added here:

***********************************
** outputs to other ddck
***********************************

** Add here the outputs of the TYPE or TYPES that will be used in other types
** Exception: those for printers and so on dont need to be here.

Precalculations related to parameter scaling and pre-processing

Usually, in the declaration of a TRNSYS component, many parameters are calculated out of more general system variables. All calculations to determine the right parameters inputs for the type go here:

***********************************
** Begin CONSTANTS
***********************************

Type section

TRNSYS has its own syntax that calls the type dll files. This core part of the ddck goes here:

***********************************
** Begin TYPE
***********************************

Component printers

Each component should have a monthly as well as an hourly printer. This helps to simplify the setup and the processing of the simulation. In addition, an online plotter is a nice tool for the debugging of the system:

***********************************
** Monthly printer
***********************************

***********************************
** Hourly printer
***********************************

***********************************
** Online plotter
***********************************

Hydraulics files

The hydraulics file represents the systems hydraulics layout. Each pytrnsys example system except the pv battery system has its own hydraulic layout file. In order to create your own hydraulic files that represent the hydraulics of your choice you need access to the pytrnsys GUI. The hydraulics file are not part of the ddck repository. The hydraulic files of the example systems are located in the example system folder of pytrnsys_examples.

Examples

The following example shows the ddck file of the solar collector type 1 used in the solar domestic hot water system:

*******************************
**BEGIN Type1.ddck
*******************************

*****************************************
** Contact person : Dani Carbonell
** Creation date  : 10.01.2010
** Last changes   : 03.2020 Jeremias Schmidli
*****************************************

***************************************************************************
** Description:
** Collector model using efficiency curve efficiency
***************************************************************************

***********************************
** inputs from hydraulic solver
***********************************

EQUATIONS 2
TCollIn = @temp(CollIn)
MfrColl = @mfr(CollIn)

***********************************
** outputs to hydraulic solver
***********************************

EQUATIONS 1
TCollOut = [28,1]

***********************************
** outputs to other ddck
***********************************

******************************************************************************************
** outputs to energy balance in kWh and ABSOLUTE value
** Following this naming standard : qSysIn_name, qSysOut_name, elSysIn_name, elSysOut_name
******************************************************************************************

EQUATIONS 1
qSysIn_Collector = PColl_kW

***********************************
** Dependencies with other ddck
***********************************

EQUATIONS 1
pumpColOn = puColOn

CONSTANTS 2
C_tilt = slopeSurfUser_1  ! @dependencyDdck Collector tilt angle / slope [°]
C_azim = aziSurfUSer_1    ! @dependencyDdck Collector azimuth  (0:s, 90:w, 270: e) [°]

EQUATIONS 4
**surface-8
IT_Coll_kJhm2 = IT_surfUser_1  ! Incident total radiation on collector plane, kJ/hm2
IB_Coll_kJhm2 = IB_surfUser_1  ! incident beam radiation on collector plane, kJ/hm2
ID_Coll_kJhm2 = ID_surfUser_1  ! diffuse and ground reflected irradiance on collector tilt
AI_Coll = AI_surfUser_1  ! incident angle on collector plane, °

EQUATIONS 5
IT_Coll_kW = IT_Coll_kJhm2/3600     ! Incident total radiation on collector plane, kW/m2
IB_Coll_kW = IB_Coll_kJhm2/3600     ! incident beam radiation on collector plane, kW/m2
ID_Coll_kW = ID_Coll_kJhm2/3600     ! diffuse and ground reflected irradiance on collector tilt (kW/m2)
IT_Coll_Wm2 = IT_surfUser_1/3.6
IT_Coll_kWm2 = IT_surfUser_1/3600

***********************************
** Begin CONSTANTS
***********************************

CONSTANTS 3
MfrCPriSpec = 15  ! Coll. Prim. loop spec. mass flow [kg/hm2]
AcollAp=5         ! Collector area
MfrCPriNom = MfrCPriSpec*AcollAp !

***********************************
** Begin TYPE
***********************************

UNIT 28 TYPE 1
PARAMETERS 11
nSeries       ! number in series
AcollAp       ! collector area
cpBri          ! fluid specific heat kj(kgK
efficiencyMode ! efficiency mode
testedMfr      ! tested flow rate kg/(hm2)
Eta0          ! intercept efficiency
a1            ! efficiency slope kJ/hm^2K
a2            ! efficiency curvature kJ/hm^2K^2
2             ! optical mode
FirstOrderIAM  ! 1st order IAM
SecondOrderIAM ! 2nd order IAM
INPUTS 9
TCollIn
MfrColl
Tamb
IT_Coll_kJhm2
IT_H
ID_Coll_kJhm2
0,0
AI_Coll !Flo check ! JS: This was defined wrong before (C_azim, even though it is incident angle input). Now it should be correct.
C_tilt !Flo check  ! JS: This should be correct
*** INITIAL INPUT VALUES
20 0 10 0 0 0 GroundReflectance 45 0

EQUATIONS 4
**MfrCout = [700,2]
Pcoll = [28,3] !kJ/h
PColl_kW = Pcoll/3600
PColl_kWm2 = PColl_kW/(AcollAp+1e-30)
PColl_Wm2  = PColl_kWm2*1000


***********************************
** Monthly printer
***********************************

CONSTANTS 1
unitPrintSol = 31

ASSIGN temp\SOLAR_MO.Prt unitPrintSol

UNIT 32 TYPE 46
PARAMETERS 6
unitPrintSol ! 1: Logical unit number, -
-1           ! 2: Logical unit for monthly summaries, -
1            ! 3: Relative or absolute start time. 0: print at time intervals relative to the simulation start time. 1: print at absolute time intervals. No effect for monthly integrations
-1           ! 4: Printing & integrating interval, h. -1 for monthly integration
1            ! 5: Number of inputs to avoid integration, -
1            ! 6: Output number to avoid integration
INPUTS 4
Time  Pcoll_kW  PColl_kWm2  IT_Coll_kWm2
**
Time  Pcoll_kW  PColl_kWm2  IT_Coll_kWm2

***********************************
** Hourly printer
***********************************

CONSTANTS 1
unitHourlyCol = 33

ASSIGN    temp\SOLAR_HR.Prt    unitHourlyCol

UNIT 34 TYPE 46     ! Printegrator Monthly Values for System
PARAMETERS 7
unitHourlyCol ! 1: Logical unit number, -
-1            ! 2: Logical unit for monthly summaries, -
1             ! 3: Relative or absolute start time. 0: print at time intervals relative to the simulation start time. 1: print at absolute time intervals. No effect for monthly integrations
1             ! 4: Printing & integrating interval, h. -1 for monthly integration
2             ! 5: Number of inputs to avoid integration, -
4             ! 6: Output number to avoid integration
5             ! 7: Output number to avoid integration
INPUTS 6
Pcoll_kW  PColl_kWm2  IT_Coll_kWm2 TCollOut TCollIn MfrColl
**
Pcoll_kW  PColl_kWm2  IT_Coll_kWm2 TCollOut TCollIn MfrColl

A specific parametrization can be added by using a ddck from the database for example the type1_CONSTANTS_cOBRAak2_8v.ddck:

******************************
**BEGIN Type1_Constants_CobraAK2_8V.ddck
*******************************

*****************************************
** Solar Thermal Data for covered collector.
** Very well performing collector Cobra AK 2.8V
** Version : v0.0
** Last Changes: Jeremias Schmidli
** Date: 10.03.2020
******************************************

CONSTANTS 11

Eta0= 0.857     ! Eta0 (a0) of collector (zero heat loss efficiency)
a1 = 4.16*3.6    ! linear heat loss coefficient of collector [kJ/hm^2K] ![W/m2K]*3.6
a2 = 0.0089*3.6   ! quadratic heat loss coefficient of collector [kJ/hm^2K^2] ![W/m2K2]*3.6

AbsorberArea = 2.435 !m2
TotArea = 2.768 !m2

nSeries = 1
efficiencyMode = 1
testedMfr = 200/AbsorberArea !l/hm2

GroundReflectance = 0.2

FirstOrderIAM = 0.108
SecondOrderIAM = 0
*******************************
**END Type1_Constants_Test.ddck
*******************************

Placeholder statements with specific syntax can be added to the inputs from hydraulic solver and Outputs to the hydraulic solver in ddck:

*******************************
**BEGIN Type1.ddck
*******************************

*****************************************
** Contact person : Dani Carbonell
** Creation date  : 10.01.2010
** Last changes   : 18.05.2022
*****************************************

***************************************************************************
** Description:
** Collector model using efficiency curve efficiency
***************************************************************************

***********************************
** inputs from hydraulic solver
***********************************
EQUATIONS 2
TCollIn = @temp(In, TPiColIn)
MfrColl = ABS(@mfr(In, MfrPiColIn))

***********************************
** outputs to hydraulic solver
***********************************
EQUATIONS 2
TCollOut = [28,1]
@temp(Out) = TCollOut

***********************************
** outputs to other ddck
***********************************

******************************************************************************************
** outputs to energy balance in kWh and ABSOLUTE value
** Following this naming standard :
** qSysIn_name, qSysOut_name, elSysIn_name, elSysOut_name
******************************************************************************************
EQUATIONS 1
qSysIn_Collector = PColl_kW

***********************************
** Dependencies with other ddck
***********************************
EQUATIONS 1
pumpColOn = puColOn

CONSTANTS 2
C_tilt = slopeSurfUser_1            ! @dependencyDdck Collector tilt angle / slope [°]
C_azim = aziSurfUSer_1              ! @dependencyDdck Collector azimuth  (0:s, 90:w, 270: e) [°]

EQUATIONS 4
**surface-8
IT_Coll_kJhm2 = IT_surfUser_1               ! Incident total radiation on collector plane, kJ/hm2
IB_Coll_kJhm2 = IB_surfUser_1               ! incident beam radiation on collector plane, kJ/hm2
ID_Coll_kJhm2 = ID_surfUser_1               ! diffuse and ground reflected irradiance on collector tilt
AI_Coll = AI_surfUser_1                     ! incident angle on collector plane, °

EQUATIONS 5
IT_Coll_kW = IT_Coll_kJhm2/3600             ! Incident total radiation on collector plane, kW/m2
IB_Coll_kW = IB_Coll_kJhm2/3600     ! incident beam radiation on collector plane, kW/m2
ID_Coll_kW = ID_Coll_kJhm2/3600     ! diffuse and ground reflected irradiance on collector tilt (kW/m2)
IT_Coll_Wm2 = IT_surfUser_1/3.6
IT_Coll_kWm2 = IT_surfUser_1/3600

***********************************
** Begin CONSTANTS
***********************************
CONSTANTS 3
MfrCPriSpec = 15            ! Coll. Prim. loop spec. mass flow [kg/hm2]
AcollAp = 5                 ! Collector area
MfrCPriNom = MfrCPriSpec*AcollAp

***********************************
** Begin TYPE
***********************************
UNIT 28 TYPE 1
PARAMETERS 11
nSeries                     ! number in series
AcollAp                     ! collector area
cpBri                       ! fluid specific heat kj(kgK
efficiencyMode              ! efficiency mode
testedMfr                   ! tested flow rate kg/(hm2)
Eta0                        ! intercept efficiency
a1                          ! efficiency slope kJ/hm^2K
a2                          ! efficiency curvature kJ/hm^2K^2
2                           ! optical mode
FirstOrderIAM               ! 1st order IAM
SecondOrderIAM              ! 2nd order IAM
INPUTS 9
TCollIn
MfrColl
Tamb
IT_Coll_kJhm2
IT_H
ID_Coll_kJhm2
0,0
AI_Coll             !Flo check              ! JS: This was defined wrong before (C_azim, even though it is incident angle input). Now it should be correct.
C_tilt              !Flo check              ! JS: This should be correct
*** INITIAL INPUT VALUES
20 0 10 0 0 0 GroundReflectance 45 0

EQUATIONS 4
**MfrCout = [700,2]
Pcoll = [28,3]              !kJ/h
PColl_kW = Pcoll/3600
PColl_kWm2 = PColl_kW/(AcollAp+1e-30)
PColl_Wm2  = PColl_kWm2*1000

***********************************
** Monthly printer
***********************************
CONSTANTS 1
unitPrintSol = 31

ASSIGN temp\SOLAR_MO.Prt unitPrintSol

UNIT 32 TYPE 46
PARAMETERS 6
unitPrintSol                ! 1: Logical unit number, -
-1                          ! 2: Logical unit for monthly summaries, -
1                           ! 3: Relative or absolute start time. 0: print at time intervals relative to the simulation start time. 1: print at absolute time intervals. No effect for monthly integrations
-1                          ! 4: Printing & integrating interval, h. -1 for monthly integration
1                           ! 5: Number of inputs to avoid integration, -
1                           ! 6: Output number to avoid integration
INPUTS 4
Time  Pcoll_kW  PColl_kWm2  IT_Coll_kWm2
**
Time  Pcoll_kW  PColl_kWm2  IT_Coll_kWm2

***********************************
** Hourly printer
***********************************
CONSTANTS 1
unitHourlyCol = 33

ASSIGN    temp\SOLAR_HR.Prt    unitHourlyCol

UNIT 34 TYPE 46             ! Printegrator Monthly Values for System
PARAMETERS 7
unitHourlyCol               ! 1: Logical unit number, -
-1                          ! 2: Logical unit for monthly summaries, -
1                           ! 3: Relative or absolute start time. 0: print at time intervals relative to the simulation start time. 1: print at absolute time intervals. No effect for monthly integrations
1                           ! 4: Printing & integrating interval, h. -1 for monthly integration
2                           ! 5: Number of inputs to avoid integration, -
4                           ! 6: Output number to avoid integration
5                           ! 7: Output number to avoid integration
INPUTS 6
Pcoll_kW  PColl_kWm2  IT_Coll_kWm2 TCollOut TCollIn MfrColl
**
Pcoll_kW  PColl_kWm2  IT_Coll_kWm2 TCollOut TCollIn MfrColl

***********************************
** Online Plotter
***********************************
UNIT 103 TYPE 65            !Changed automatically
PARAMETERS 12
4                                   ! 1: Nb. of left-axis variables
2                                   ! 2: Nb. of right-axis variables
0                                   ! 3: Left axis minimum
10                                  ! 4: Left axis maximum
0                                   ! 5: Right axis minimum
100                                 ! 6: Right axis maximum
nPlotsPerSim                ! 7: Number of plots per simulation
12                                  ! 8: X-axis gridpoints
1                                   ! 9: Shut off Online w/o removing
-1                                  ! 10: Logical unit for output file
0                                   ! 11: Output file units
0                                   ! 12: Output file delimiter
INPUTS 6
Pcoll_kW  PColl_kWm2  IT_Coll_kWm2  MfrColl
TCollOut TCollIn
Pcoll_kW  PColl_kWm2  IT_Coll_kWm2  MfrColl
TCollOut TCollIn
LABELS  3
Power_and_Mfr
Temperatures
Collector

*******************************
**END Type1.ddck
*******************************