Update operating state validation logic
Browse files Browse the repository at this point in the history
Track raw temperature and raw setpoint values from the thermostat and compare those
  • Loading branch information
dkirker committed Dec 20, 2018
1 parent 438a14d commit ff60781
Showing 1 changed file with 59 additions and 12 deletions.
Expand Up @@ -244,13 +244,14 @@ def parse(String description) {
def intVal = Integer.parseInt(descMap.value, 16)
// We receive 0x8000 when the thermostat is off
if (intVal != 0x8000) {
state.rawSetpoint = intVal
log.debug "HEATING SETPOINT"
map.name = "heatingSetpoint"
map.value = getTemperature(descMap.value)
map.unit = getTemperatureScale()
map.data = [heatingSetpointRange: heatingSetpointRange]

handleOperatingStateBugfix(map.value, null)
handleOperatingStateBugfix()
}
} else if (descMap.attrInt == ATTRIBUTE_SYSTEM_MODE) {
log.debug "MODE - ${descMap.value}"
Expand Down Expand Up @@ -306,6 +307,11 @@ def parse(String description) {
!secondsPast(device.currentState("thermostatOperatingState")?.getLastUpdated(), 30)) {
map.displayed = false
}
map = validateOperatingStateBugfix(map)
// Check to see if this was changed, if so make sure we have the correct heating setpoint
if (map.data?.correctedValue) {
sendHubCommand(zigbee.readAttribute(THERMOSTAT_CLUSTER, ATTRIBUTE_HEAT_SETPOINT))
}
}
}
}
Expand Down Expand Up @@ -335,6 +341,7 @@ def handleTemperature(descMap) {
if (intVal > 0x8000) { // Handle negative C (< 32F) readings
intVal = -(Math.round(2 * (65536 - intVal)) / 2)
}
state.rawTemp = intVal
map.name = "temperature"
map.value = getTemperature(intVal)
map.unit = getTemperatureScale()
Expand All @@ -354,30 +361,70 @@ def handleTemperature(descMap) {
sendEvent(name: "temperatureAlarm", value: "cleared")
}

handleOperatingStateBugfix(null, map.value)
handleOperatingStateBugfix()
}

map
}

// Due to a bug in this model's firmware, sometimes we don't get
// an updated operating state; so we will force it.
// an updated operating state; so we need some special logic to verify the accuracy.
// TODO: Add firmware version check when change versions are known
def handleOperatingStateBugfix(setpoint, temp) {
def currSetpoint = (setpoint != null) ? setpoint : device.currentValue("heatingSetpoint")
def ambientTemp = (temp != null) ? temp : device.currentValue("temperature")
// The logic between these two functions works as follows:
// In temperature and heatingSetpoint events check to see if we might need to request
// the current operating state and request it with handleOperatingStateBugfix.
//
// In operatingState events validate the data we received from the thermostat with
// the current environment, adjust as needed. If we had to make an adjustment, then ask
// for the setpoint again just to make sure we didn't miss data somewhere.
//
// There is a risk of false positives where we receive a new valid operating state before the
// new setpoint, so we basically toss it. When we come to receiving the setpoint or temperature
// (temperature roughly every minute) then we should catch the problem and request an update.
// I think this is a little easier than outright managing the operating state ourselves.
// All comparisons are made using the raw integer from the thermostat (Celsius decimal * 100)
// that is stored in temperature and setpoint events.

/**
* Check if we should request the operating state, and request it if so
*/
def handleOperatingStateBugfix() {
def currOpState = device.currentValue("thermostatOperatingState")

if (currSetpoint != null && ambientTemp != null) {
if (currSetpoint <= ambientTemp) {
if (state.rawSetpoint != null && state.rawTemp != null) {
if (state.rawSetpoint <= state.rawTemp) {
if (currOpState != "idle")
sendEvent(name: "thermostatOperatingState", value: "idle")
sendHubCommand(zigbee.readAttribute(THERMOSTAT_CLUSTER, ATTRIBUTE_PI_HEATING_STATE))
} else {
if (currOpState != "heating")
sendEvent(name: "thermostatOperatingState", value: "heating")
sendHubCommand(zigbee.readAttribute(THERMOSTAT_CLUSTER, ATTRIBUTE_PI_HEATING_STATE))
}
}
}
/**
* Given an operating state event, check its validity against the current environment
* @param map An operating state to validate
* @return The passed map if valid, or a corrected map and a new param data.correctedValue if invalid
*/
def validateOperatingStateBugfix(map) {
// If we don't have historical data, we will take the value we get,
// otherwise validate if the difference is > 1
if (state.rawSetpoint != null && state.rawTemp != null) {
def oldVal = map.value

if (state.rawSetpoint <= state.rawTemp) {
map.value = "idle"
} else {
map.value = "heating"
}

// Indicate that we have made a change
if (map.value != oldVal) {
map.data = [correctedValue: true]
}
}
map
}

def updateWeather() {
log.debug "updating weather"
Expand Down Expand Up @@ -574,10 +621,10 @@ def configure() {
requests += zigbee.addBinding(THERMOSTAT_CLUSTER)
// Configure Thermostat Cluster
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_LOCAL_TEMP, DataType.INT16, 10, 60, 50)
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_HEAT_SETPOINT, DataType.INT16, 1, 0, 50)
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_HEAT_SETPOINT, DataType.INT16, 1, 180, 50)
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_SYSTEM_MODE, DataType.ENUM8, 1, 0, 1)
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_MFR_SPEC_SETPOINT_MODE, DataType.ENUM8, 1, 0, 1)
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_PI_HEATING_STATE, DataType.UINT8, 1, 900, 1)
requests += zigbee.configureReporting(THERMOSTAT_CLUSTER, ATTRIBUTE_PI_HEATING_STATE, DataType.UINT8, 1, 180, 1)

// Configure Thermostat Ui Conf Cluster
requests += zigbee.configureReporting(THERMOSTAT_UI_CONFIG_CLUSTER, ATTRIBUTE_TEMP_DISP_MODE, DataType.ENUM8, 1, 0, 1)
Expand Down