Calibration menu shows ">No printer", can't seem to use Calibration menu #2197

Closed
2 tasks done
cjshaker opened this issue Sep 21, 2023 · 6 comments
Closed
2 tasks done
Labels
bug Something isn't working stale

Comments

@cjshaker
Copy link

cjshaker commented Sep 21, 2023

OrcaSlicer Version

1.7.0

OS version

Windows 11 Home 22H2 build 22621.2283

Additional system information

Device name cjshaker
Processor 11th Gen Intel(R) Core(TM) i7-11700K @ 3.60GHz 3.60 GHz
Installed RAM 16.0 GB (15.8 GB usable)
Device ID B5CDE8A9-447B-48FE-B136-D7E01C09CC4B
Product ID 00325-82189-88851-AAOEM
System type 64-bit operating system, x64-based processor
Pen and touch No pen or touch input is available for this display

Printer

Flsun V400, and Prusa MK3S

How to reproduce

I'm a new Orca Slicer user. Apologize in advance if this is just operator error, but the wiki doesn't appear to show this?

Click 'New Project', select Flsun V400 printer, select a filament (like FlSun Generic PLA), select 0.20mm Standard@FLSun V400 for print quality, select 'Preview' tab - all looks good. Now, select 'Calibration' tab to the right of 'Project', and nothing works:
FlsunV400Selected
FlowDynamicsGreyedOut
FlowRateGreyedOut

ALSO, the 'Project' tab says 'no model information'. Is this expected?
ProjectNoModelInfo

I tried the same thing with the Prusa i3 MK3 printer, and that 'Calibration' tab is also greyed out for that printer too:
MK3S Selected
CalibrationNotWorking2

Either I'm missing something in the user interface, or this 'Calibration' tab is broken in 1.7.0?

Hmm. I just noticed the "Calibration" in the TOP menu bar, and that appears to work.
Also, the "Calibration" in the TOP menu bar only works if you are in the 'Prepare' tab.
Why are there TWO ways of doing Calibration?

Actual results

Can't select 'Manual Calibration' nor 'Auto Calibration'. Calibration says "> No printer". Screenshots above.

Expected results

I thought I used to be able to launch calibration in a previous version of Orca slicer?

Project file & Debug log uploads

Project.zip
debug_Thu_Sep_21_14_45_00_3296.log.zip
OrcaSlicer.conf.zip

Checklist of files to include

  • Log file
  • Project file
@cjshaker cjshaker added the bug Something isn't working label Sep 21, 2023
@Noisyfox
Copy link
Collaborator

Noisyfox commented Sep 22, 2023

Because the calibration tab is added in BambuStudio and only works for their printers, while the one on menu bar is the Orca's own calibration tools (which was added earlier than bambu's).

Same for the Project tab, which is also bambu specific.

@YELLOWFROG0623
Copy link

Hi!
Sorry for cutting in.
I went through the same process of trial and error for about 2 days, but I finally solved the mystery and felt refreshed.
thank you very much.

@DrDrache
Copy link

can we get an option to remove (hide) the tab for non-bamboo printers? or perhaps get it working for others?

@stopanko
Copy link

So confusing.
image
Bambu Calibrationts. Works only with Bambu printers.

image
Orca calibrations. Free to use))

SoftFever added a commit that referenced this issue Sep 30, 2023
…2259)

* Hide bambu-specific calibration tab for non-bambu printers (#2197)

* Hide Calibration tab only

---------

Co-authored-by: SoftFever <softfeverever@gmail.com>
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 1, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 1, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
igiannakas added a commit to igiannakas/OrcaSlicer that referenced this issue Oct 19, 2023
Copy link

GitHub bot: this issue is stale because it has been open for 90 days with no activity.

@github-actions github-actions bot added the stale label Dec 29, 2023
@Noisyfox
Copy link
Collaborator

Should have been fixed a while ago by hiding the bambu calibration tab for non-bambu printers.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment