StructuralCurveActionThermal

Thermal load on the beam

The thermal load on the line elements (StructuralCurveMember, StructuralCurveMemberRib). The variation of the thermal load can be constant or linear over the cross-section of the beam.

Specification in the excel

Column header Data type Example / enum definition Required Description
Name String LT1 yes Human readable unique name of the load
Force action Enum

On beam

On rib

yes Specifies on which type of object the load acts.
Variation Enum

Constant

Linear

yes

Specifies how the temperature varies

Constant: The load is defined by means of a single value deltaT. The value specifies the warming to which the 1D member is subject to.

Linear: The load is defined by means of a set of four values. The individual values specify the temperature at individual sides (left, right, top, bottom) of the 1D member.

deltaT [°C] Double 5 yes; if Variation = Constant

Temperature delta in Celsius/Fahrenheit on the centre line of the member.

*See note to clarify the position.

TempL [°C] Double 5 yes, if Variation = Linear

The temperature on the left side of the beam surface in Celsius/Fahrenheit. Refers to LCS of 1D member.

*See note to clarify the position.

TempR [°C] Double 18 yes, if Variation = Linear

Temperature on right side of the beam surface in Celsius/Fahrenheit. Refers to LCS of 1D member.

*See note to clarify the position.

TempT [°C] Double 5 yes, if Variation = Linear

Temperature on top side of the beam surface in Celsius/Fahrenheit. Refers to LCS of 1D member.

*See note to clarify the position.

TempB [°C] Double 5 yes, if Variation = Linear

Temperature on bottom side of the beam surface in Celsius/Fahrenheit. Refers to LCS of 1D member.

*See note to clarify the position.

Member String B11 yes, if Force action = On beam The name of the StructuralCurveMember on which the load is applied
Member Rib String B10 yes, if Force action = On rib The name of the StructuralCurveMemberRib on which the load is applied
Load case String LC1 yes The name of the load case to which the load belongs
Coordinate definition Enum

Absolute

Relative

yes Selects the coordinate system that is used to define the length of the line load. Relative means without units. To define length of the load in meters input absolute
Origin Enum

From start

From end

yes Specifies the origin of the coordinate system used for the definition of the length of the load
Start point [m] Double

value in meters for Coordinate definition = Absolute

0,0

value in percentage for Coordinate definition = Relative

0,0

yes Defines the position of the start point of the load in relative or absolute coordinates
End point [m] Double

value in meters for Coordinate definition = Absolute

5,25

value in percentage for Coordinate definition = Relative

1,0

yes Defines the position of the end point of the load in relative or absolute coordinates
Parent ID String 67b35d84-3d04-47aa-aa4a-dc1263982320 no

Is filled for objects created be dividing curved geometry to series of straight line objects.

Parent ID will ensure that curved edge is imported as straight parts to nonsupporting application, and back to original supporting application as curved geometry.

To ensure successful round trip of segmented objects and their related objects, Parent ID needs to be present in both directions.

Id String 39f238a5-01d0-45cf-a2eb-958170fd4f39 no Unique attribute designation

Notes

Reference to surfaces of cross-section where linear temperature can be applied. View is towards the direction of center axis (looking from end point towards start point).