Hi. I just added Intel AMT on, off and reset to MeshCtrl "devicepower" command, this will be in MeshCentral v1.0.28. Note that when using Intel AMT only (no agent) you can do wake (on) and power off and reset from the group action. MeshCentral should automatically using Intel AMT to perform these actions when you select "Wake-up devices", "Power off devices" or "Reset devices". Let me know if it works. |
Awesome, thank you so much. I'm only seeing 1.0.27 under Latest version, when will 1.0.28 be available? |
v1.0.28 will probably be release later today. |
@Ylianst How can I help you with this so you can include the information yourself? |
Hi @Ylianst, we upgraded to 1.0.28 and the group actions don't work. For group action we have power off devices, reset devices, and wake devices. But the new MeshCtrl commands --amtoff, --amton, and --amtreset do work, they also work from the web gui when you go into the host and click on actions and we see Intel AMT reset, Intel AMT Power On, and Intel AMT Power Off. Thanks |
Hi again Ylianst, after further use we noticed that when you go into any device and then go to the Intel AMT tab, the Connect button no longer works. It doesn't connect to any of our AMT hosts. |
I've noticed this as well so I have went back to the stable version same thing happens in 1.0.27 as well. |
@Ylianst, any news on when this might be resolved. Thanks. |
@Ylianst Pinging request, have you had a chance to look at this again? thanks |
Any update on this? |
Unfortunately the group power off function is not working, has anyone else found a fix or another version that works? |
@si458 AMT and stale |
We are still having this issue as well. |
@aztlanla if the intel AMT options to reset/poweroff are working, then great, please can you close this issue |
@si458 This ticket is for the group actions AMT Reset or AMT Power off and those are still not working. |
@aztlanla right ok no worries, sadly i have 0 computers that support AMT, so i cannot test/fix this issue, but ill have a look at code in background incase its something very basic/simple! EDIT: after checking the sourcecode, the 'Power off devices' and 'Reset devices' are just standard poweraction commands, |
@aztlanla can you check if meshctrl works? |
Ok, I'll check this week and reply back. Thanks |
Hi, we would like the ability to do an AMT Reset or AMT Power off from group actions and/or from the meshctrl cmdline tool.
Currently, only wake works using DevicePower from meshctrl and group actions. We are not using the agent on our hosts, just AMT.
We can do this from MeshCentral going to host | Intel AMT tab | Connect | System Status | Power Actions | Reset