Objective: Design a Power Converter and Integrate it with PV Module, finally check its performance using (i) Ćuk Converter, and (ii) SEPIC Converter. However, before designing the performance and efficiency of a PV Module is checked with Buck-Boost Converter and the results are compared.
NOTE: Before Desiging, please note the following Modelling Configuration Parameters:
- Type: Fixed Step,
- Solver: discrete (no continuous states),
-
Solver Details: Sampling Time
10e-6
(i.e.$t = 10 \mu s$ ), and - Also, set the powergui with same configuration
PV Array in Simulink has many in-built pre-developed module configured, one such is the 1Soltech - 1STH-215-P. Here, this module has been used whose electrical properties is as follows:
Value | |
---|---|
Max. Power ( |
213.13 W |
Open Circuit Voltage ( |
36.3 V |
Sc. Current ( |
7.84 A |
Max. Voltage @MPP ( |
29 V |
Max. Current@MPP ( |
7.35 A |
PV Array Configuration: Approx. 1 kW Array (with 5 Parallel Strings, and 1 Series Connected Module/String). Charecteristic Curve is as below: