Notifications
You must be signed in to change notification settings - Fork 1
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Move supported mode function to helper
Signed-off-by: Andy Blyler <andy@blyler.cc>
- Loading branch information
Showing
2 changed files
with
56 additions
and
50 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,47 @@ | ||
from typing import List | ||
|
||
from .constants import BradfordWhiteConnectHeatingModes | ||
|
||
|
||
def get_appliance_model_heating_modes(appliance_model: str) -> List[int]: | ||
""" | ||
This function returns the heating modes available for a given appliance model. | ||
Parameters: | ||
appliance_model (str): The model number of the appliance. | ||
Returns: | ||
List[int]: A list of heating modes available for the appliance model. The heating modes are represented as integers. | ||
The function checks if the provided model number is in the list of model numbers that do not support the Hybrid Plus mode. | ||
If the model number is in the list, the function returns a list of heating modes excluding the Hybrid Plus mode. | ||
Otherwise, it returns a list of heating modes including the Hybrid Plus mode. | ||
The heating modes are sourced from the BradfordWhiteConnectHeatingModes enumeration. | ||
Note: The model numbers are sourced from: | ||
https://forthepro.bradfordwhite.com/our-products/usa-residential-heat-pump/aerotherm-series-heat-pump/ | ||
""" | ||
|
||
model_numbers_without_hybrid_plus = [ | ||
"RE2H50S10-1NCWT", | ||
"RE2H65T10-1NCWT", | ||
"RE2H80T10-1NCWT", | ||
] | ||
|
||
# return the heating modes based on the model number | ||
if appliance_model in model_numbers_without_hybrid_plus: | ||
return [ | ||
BradfordWhiteConnectHeatingModes.ELECTRIC, | ||
BradfordWhiteConnectHeatingModes.HEAT_PUMP, | ||
BradfordWhiteConnectHeatingModes.VACATION, | ||
BradfordWhiteConnectHeatingModes.HYBRID, | ||
] | ||
else: | ||
return [ | ||
BradfordWhiteConnectHeatingModes.ELECTRIC, | ||
BradfordWhiteConnectHeatingModes.HEAT_PUMP, | ||
BradfordWhiteConnectHeatingModes.VACATION, | ||
BradfordWhiteConnectHeatingModes.HYBRID, | ||
BradfordWhiteConnectHeatingModes.HYBRID_PLUS, | ||
] |