Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Remove forced mode at end of set_heatr_conf #71

Open
wants to merge 1 commit into
base: main
Choose a base branch
from

Conversation

FoamyGuy
Copy link
Contributor

This change is an attempt to resolve: #69

I tested this change successfully on a Feather S3 TFT 9.0.3 with an Adafruit BME680 connected via stemma cable. With this change while running the simpletest script the first values printed are no longer wrong and static.

As far as I can tell the readings look reasonably correct to me, but I didn't do any accuracy comparisons against any other known calibrated source. Manipulating temperature, humidity, and gas in the environment the sensor is in appear to change their respective values as expected.

@puterboy , @DL3KB if either of you are able to test this, any additional testing is greatly appreciated.

@FoamyGuy FoamyGuy requested a review from a team April 29, 2024 14:28
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
1 participant