Skip to content

Commit

Permalink
skeleton: fixed hard-coding of master OCC hwmon sysfs path for PowerC…
Browse files Browse the repository at this point in the history
…ap object

Currently master OCC hwmon sysfs path is hardcoded to '/sys/class/hwmon/hwmon3/'.
This make the '/org/openbmc/sensors/host/PowerCap' interface cannot work when
master OCC is initilized as hwmon device other than 'hwmon3'.

'usr_powercap' attribute should be searched when OCC is active.
When skeleton creates 'PowerCap' objects, OCC may not be active.
So do the search each time setting power cap. Raise an exception when
there is no 'user_powercap' attribute.
Fixes: openbmc#42

Also raise an exception when setting power cap fails. The exception
will be returned to REST API caller. Need to specify the exception
name to trigger a '400' return code.
Fixes: openbmc#43

Add code to validate input user powercap value.

Changed the logic of "reading powercap" using PowerCap.getValue().
Previously PowerCap.getValue() returns current user set powercap value.
Now PowerCap.getValue() returns actual system powercap reading from OCC.

Signed-off-by: Yi Li <adamliyi@msn.com>
  • Loading branch information
adamliyi committed Mar 4, 2016
1 parent 7af0c35 commit 96dfd7c
Show file tree
Hide file tree
Showing 2 changed files with 47 additions and 12 deletions.
56 changes: 47 additions & 9 deletions bin/Sensors.py
@@ -1,13 +1,13 @@
#!/usr/bin/python -u

import sys
import subprocess
#from gi.repository import GObject
import gobject
import dbus
import dbus.service
import dbus.mainloop.glib
import os
import glob
import Openbmc

## Abstract class, must subclass
Expand Down Expand Up @@ -137,21 +137,59 @@ class PowerCap(VirtualSensor):
def __init__(self, bus, name):
VirtualSensor.__init__(self, bus, name)
SensorValue.setValue(self, 0)
self.sysfs_attr = "/sys/class/hwmon/hwmon3/user_powercap"
##override setValue method
@dbus.service.method(SensorValue.IFACE_NAME,
in_signature='v', out_signature='')
def setValue(self, value):
try:
cmd_str = "echo "+str(value)+" > "+self.sysfs_attr
ret = subprocess.check_output(cmd_str, shell=True)
except subprocess.CalledProcessError as powerexc:
print "Set PowerCap Error", powerexc.returncode,
powerexc.output
return
value = int(value)
except ValueError:
raise dbus.exceptions.DBusException(
"Set an integer value",
name='org.freedesktop.DBus.Python.TypeError')

# master occ hwmon path is created dymanically when occ is active
# scan hwmon sysfs directory for update
for pcap_file in glob.glob('/sys/class/hwmon/*/user_powercap'):
occ_i2c_dev = os.path.dirname(pcap_file)+'/device'
occ_i2c_dev = os.path.realpath(occ_i2c_dev).split('/').pop()
if occ_i2c_dev == '3-0050':
setcap_file = pcap_file
break
else:
raise dbus.exceptions.DBusException(
"Cannot find user_powercap hwmon attribute, "+
"check occ status.",
name='org.freedesktop.DBus.Python.TypeError')

# verify the user set value is in the range [min_cap, max_cap]
try:
caps_file = open(os.path.dirname(setcap_file) +
'/caps_min_powercap', 'r')
min_cap = caps_file.readline()
caps_file = open(os.path.dirname(setcap_file) +
'/caps_max_powercap', 'r')
max_cap = caps_file.readline()
except IOError:
raise dbus.exceptions.DBusException(
"Cannot get caps_min or caps_max",
name='org.freedesktop.DBus.Error.InvalidArgs')

if value != 0 and (value < int(min_cap) or value > int(max_cap)):
raise dbus.exceptions.DBusException(
"Set a value in the range [%d, %d]"
% (int(min_cap), int(max_cap)),
name='org.freedesktop.DBus.Error.InvalidArgs')

try:
open(setcap_file, 'w').write(str(value));
except IOError:
raise dbus.exceptions.DBusException(
"Cannot set PowerCap",
name='org.freedesktop.DBus.Python.TypeError')
print "Set PowerCap: ", value
SensorValue.setValue(self, value)

class BootProgressSensor(VirtualSensor):
def __init__(self,bus,name):
VirtualSensor.__init__(self,bus,name)
Expand Down
3 changes: 0 additions & 3 deletions bin/sensor_manager2.py
Expand Up @@ -54,9 +54,6 @@ def SensorChange(self,value,path=None):

obj_path = OBJ_PATH+"/host/PowerCap"
sensor_obj = Sensors.PowerCap(bus,obj_path)
## hwmon3 is default for master OCC on Barreleye.
## should rewrite sensor_manager to remove hardcode
sensor_obj.sysfs_attr = "/sys/class/hwmon/hwmon3/user_powercap"
root_sensor.add(obj_path,sensor_obj)

obj_path = OBJ_PATH+"/host/BootProgress"
Expand Down