When accessing updated print settings panel I don't understand some functions which are not described in the manual https://manual.advi3pp.com/en/touch-panel-guide/print/print-settings

The panel has 2 settings.

  1. A setting under baby stroller with value 0.04
  2. A setting with a switch options 0.02, 0.1 and 1.00

The manual has reference to baby stepping, but it is not clear

  • which of 2 options is referred to
  • what is a meaning of "baby stepping"
  • what is purpose of the other option

Please make it more clear as it is unusable for me at the moment w/o support

@andrivet
Copy link
Owner

I will add a category for the manual (defect or suggestions). I will look at this soon

@andrivet andrivet added the documentation Something related to the documentation label Sep 27, 2022
@andrivet
Copy link
Owner

andrivet commented Oct 1, 2022

I will enhance the documentation. In the meantime, here is a description from Marlin’s documentation (Babystep | Marlin Firmware):

Apply babysteps to one or more axes using current units. Offsets applied with M290 aren’t added to the current coordinates, but are intended for making small adjustments, especially in the Z axis, at the start of a print.

Note that when BABYSTEP_ZPROBE_OFFSET is enabled, M290 also modifies the Probe Z Offset (with no immediate effects). The new Z offset applies to successive probing operations, and can be saved with M500. This behavior is means to coincide with the LCD Menu replacing “Z Babystepping” with “Babystep Z Probe Offset.” To avoid this side-effect, use M290 P0 or leave ?BABYSTEP_ZPROBE_OFFSET disabled.
For ADVi3++, BABYSTEP_ZPROBE_OFFSET is enabled. Pressing the checkmark triggers a M500.

See also: https://community.advi3pp.com/t/missing-how-to-manually-input-z-offset-information-on-5-4/4386/8

@andrivet andrivet added this to the 5.5.0 milestone Oct 1, 2022
@andrivet andrivet closed this as completed Nov 2, 2022