Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[FLINK-6409] [table] TUMBLE/HOP/SESSION_START/END do not resolve time field correctly #3799

Closed
wants to merge 1 commit into from

Conversation

twalthr
Copy link
Contributor

@twalthr twalthr commented Apr 28, 2017

This is a temporary fix until the next Calcite release 1.13. It adds 5 Calcite files to the Flink code base and modifies one Calcite file in order to successfully run all tests.

@fhueske
Copy link
Contributor

fhueske commented Apr 28, 2017

Thanks @twalthr for taking care of this!
Most of the files have been copied from the Calcite master, so I won't review those. The other changes look good.

+1 to merge this PR.

@twalthr, can you also create a JIRA to remove the files when Calcite 1.13 is released?

@twalthr
Copy link
Contributor Author

twalthr commented May 2, 2017

Thanks @fhueske. I will merge this and create a JIRA for it

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment