Skip to content

Reconstruction of several papers on the topic of steady-state detection/identification.

License

Notifications You must be signed in to change notification settings

auralius/steady-state-detection

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

11 Commits
 
 
 
 
 
 
 
 

Repository files navigation

steady-state-detection

Recontruction of the following papers on the topic of steady state detection / identification methods:

[1] J. D. Kelly and J. D. Hedengren, “A steady-state detection (SSD) algorithm to detect non-stationary drifts in processes,” J. Process Control, vol. 23, no. 3, pp. 326–331, 2013.

alt text

alt text

A closer probability to 1 means the more likely it is in a steady state condition.


[2] R. R. Rhinehart, “Automated steady and transient state identification in noisy processes,” in Proceedings of the American Control Conference, 2013, no. June 2013, pp. 4477–4493.

The figure below is without data windowing applied, each data point is processed immediately. It does not look so good. Perhaps, it needs more tuning for the lambda values.

alt text

The figure below is with data windowing applied. It looks nice ;-)

alt text

For this method, the lower R-value means the more likely it is in a steady state condition.


The plant that is used:

Continously stirred tank reactor (CSTR):

http://apmonitor.com/che436/index.php/Main/CaseStudyCSTR