End of gating pulse dropped at end of sequence #56

Closed
caryan opened this issue Jul 8, 2015 · 3 comments
Closed

End of gating pulse dropped at end of sequence #56

caryan opened this issue Jul 8, 2015 · 3 comments

Comments

@caryan
Copy link
Contributor

caryan commented Jul 8, 2015

Issue on both APS1 and APS2

@blakejohnson
Copy link
Collaborator

What happens on the APS2? I thought the default marker state was low on the APS2, so that it would work even if we did not emit a marker LOW instruction.

@blakejohnson
Copy link
Collaborator

Also, did some combination of 492c14c and 7a3adc0 fix this on the APS1? I can't reproduce this for the APS1.

@caryan
Copy link
Contributor Author

caryan commented Jun 27, 2016

Default state is low on APS2 and @blakejohnson seems to have fixed the APS1. Closing issue here.