Use the backend 'flags' field instead the old 'pad'. This fixes bpf compilation fails when L7 LB is used, like this: ``` level=warning msg="/var/lib/cilium/bpf/bpf_sock.c:387:14: error: no member named 'pad' in 'struct lb4_backend'" subsys=datapath-loader level=warning msg=" l7backend.pad = 0;" subsys=datapath-loader level=warning msg=" ~~~~~~~~~ ^" subsys=datapath-loader level=warning msg="1 error generated." subsys=datapath-loader ``` Add ENABLE_L7_LB to LB_OPTIONS in bpf/Makefile to catch this kind of errors in future. Fixes: #18814 Signed-off-by: Jarno Rajahalme <jarno@isovalent.com>