New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
bsunanda:Run2-alca55 Correct G4 validation code using isolated particles #15352
Conversation
A new Pull Request was created by @bsunanda for CMSSW_8_1_X. It involves the following packages: Calibration/IsolatedParticles @ghellwig, @cerminar, @cmsbuild, @franzoni, @mmusich, @davidlange6 can you please review it and eventually sign? Thanks. cms-bot commands are list here #13028 |
@cmsbuild Please test |
The tests are being triggered in jenkins. |
-1 Tested at: 1b255c6 You can see the results of the tests here: I found follow errors while testing this PR Failed tests: RelVals
When I ran the RelVals I found an error in the following worklfows: DAS Error |
@smuzaffar @davidlange6 The tests are failing because of DAS error in one example. It is happening in all PR's. Can this be fixed? |
@cmsbuild Please test |
The tests are being triggered in jenkins. |
-1 Tested at: 1b255c6 You can see the results of the tests here: I found follow errors while testing this PR Failed tests: RelVals
When I ran the RelVals I found an error in the following worklfows: DAS Error1001.0 step1 DAS Error1003.0 step1 DAS Error |
@cmsbuild Please test |
The tests are being triggered in jenkins. |
-1 Tested at: 1b255c6 You can see the results of the tests here: I found follow errors while testing this PR Failed tests: RelVals
When I ran the RelVals I found an error in the following worklfows: DAS Error |
+1 |
This pull request is fully signed and it will be integrated in one of the next CMSSW_8_1_X IBs (but tests are reportedly failing). This pull request requires discussion in the ORP meeting before it's merged. @slava77, @davidlange6, @smuzaffar |
This code is used to validate G4 physics with collision data