Accept HL7 v2 Cancel Patient Transfer/Discharge ADT^A12/A13 message by default #732

Closed
gunterze opened this issue May 29, 2017 · 0 comments
Assignees
Labels
enhancement New feature or request
Milestone

Comments

@gunterze
Copy link
Member

Accept HL7 v2 ADT Cancel messages:

  • A12 – Transfer of a patient from one location to another has been cancelled due to error
    in the information or the decision not to transfer the patient.
  • A13 – Discharge of a patient has been cancelled due to error in the information or the
    decision not to discharge the patient.

with default configuration in compliance with IHE Transaction RAD-12: Patient Update, specified in IHE Radiology Technical Framework, Volume 2 (RAD TF-2), Section 4.12.4.5 Patient Management – Cancel Patient Transfer/Discharge

@gunterze gunterze added the enhancement New feature or request label May 29, 2017
@gunterze gunterze added this to the 5.10.3 milestone May 29, 2017
@gunterze gunterze self-assigned this May 29, 2017
gunterze added a commit to dcm4che-dockerfiles/slapd-dcm4chee that referenced this issue May 29, 2017
gunterze added a commit to dcm4che/dcm4chee-arc-hl7cs that referenced this issue May 29, 2017