Notifications
You must be signed in to change notification settings - Fork 78
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Fast-slow encoder rotation increments #2
Conversation
Don't merge yet please, I made an error testing this build. NUM_DIFF was too low, so it didn't detect the fast rotation of the encoder. |
Ready to merge, please review/test before merging. Time_diff value might be too low or too high, in KSGER t12 v3 it's good. If it's too sensitive, increase it. I left it at 57 |
There is a change in time_diff when the station is powered and working, so 57ms is too low of a value, changed it to 80ms. Station seems to change sensitivity when powered to outlet, so 80 ms seems a better value.
Changed time_diff to 80 again. |
Ensure to test it properly! Will wait a bit more... |
Sure, thanks. |
As you added better support for it, pr will be closed. |
As the eevblog user "ygi" suggested, this is a pull request to add the fast-slow temperature increments.