Always enable absorption correction if absorption_level parameter set in dials.scale #1793

Merged
merged 2 commits into from
Jul 7, 2021

Conversation

jbeilstenedmands
Copy link
Contributor

The auto model rules mean that the physical-model absorption correction is turned off if the scan oscillation range is < 60 degrees. Now, if the absorption_level parameter is set, the absorption correction is enabled for all scan oscillation sizes.

This is a slight behaviour change which I believe makes the program behave more as a user would expect.

jbeilstenedmands and others added 2 commits July 7, 2021 10:48
…el parameter set.

The auto model rules mean that the physical-model absorption correction is
turned off if the scan oscillation range is < 60 degrees. Now, if the
absorption_level parameter is set, the absorption correction is enabled for
all scan oscillation sizes.
@jbeilstenedmands jbeilstenedmands merged commit af78325 into main Jul 7, 2021
@jbeilstenedmands jbeilstenedmands deleted the scaling_absorption_level_adjustment branch July 7, 2021 12:36