<?xml version="1.0" encoding="utf-8"?>
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Yale Conexis L1 (SD-L1000-CH)
http://ozw.my-ho.st/Yale/Yale%20ZWave%20Developer%20Guide.pdf
https://products.z-wavealliance.org/products/2535/configs
-->
<!-- Configuration -->
<CommandClass id="112">
<Value type="list" size="1" genre="config" instance="1" index="1" label="Volume" value="3">
<Help>Volume of the keypad tones and any voice prompts (default = 3, high)</Help>
<Item label="Silent" value="1" />
<Item label="Low" value="2" />
<Item label="High" value="3" />
</Value>
<Value type="list" size="1" genre="config" instance="1" index="2" label="Auto Relock" value="0">
<Help>Enable or disable the Auto relock feature (default = 255, enable)</Help>
<Item label="On" value="255" />
<Item label="Off" value="0" />
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="Auto-re-lock Time" size="1" min="7" max="60" units="seconds" value="30">
<Help>After successful local unlock, automatically relock after the specified time (default = 7 seconds)</Help>
</Value>
<Value type="list" size="1" genre="config" instance="1" index="4" label="Wrong Tag Limit" min="1" max="20" value="5">
<Help>
Number of incorrect tags before lock will accept before sending TAMPER Alarm.
When number of wrong code entries is exceeded, lock will disable for the time specified by Wrong tag timeout parameter. (5 = default)
</Help>
<Item label="1" value="1" />
<Item label="2" value="2" />
<Item label="3" value="3" />
<Item label="4" value="4" />
<Item label="5" value="5" />
<Item label="6" value="6" />
<Item label="7" value="7" />
<Item label="8" value="8" />
<Item label="9" value="9" />
<Item label="10" value="10" />
<Item label="11" value="11" />
<Item label="12" value="12" />
<Item label="13" value="13" />
<Item label="14" value="14" />
<Item label="15" value="15" />
<Item label="16" value="16" />
<Item label="17" value="17" />
<Item label="18" value="18" />
<Item label="19" value="19" />
<Item label="20" value="20" />
</Value>
<Value type="byte" genre="config" instance="1" index="7" label="Wrong tag timeout" size="1" min="1" max="250" units="seconds" value="30">
<Help>Number of seconds unit will be inoperable after number of Wrong tag attempts is exceeded (30 = default)</Help>
</Value>
</CommandClass>
<CommandClass id="113">
<!-- These Door Locks don't send a DoorLockReport when the
Lock Status is Changed, but instead send a Alarm Message -
So we trigger a Refresh of the DoorLock Command Class when
we recieve a Alarm Message Instead -->
<TriggerRefreshValue Genre="user" Index="0" Instance="1">
<RefreshClassValue CommandClass="98" RequestFlags="0" Index="1" Instance="1" />
</TriggerRefreshValue>
</CommandClass>
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Lifeline"/>
</Associations>
</CommandClass>
</Product>