Skip to content

dpkoch/imu_calib

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

16 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

imu_calib

This repository contains a ROS package with tools for computing and applying calibration parameters to IMU measurements.

Usage

The package contains two nodes. The first computes the accelerometer calibration parameters and saves them to a YAML file, and needs to be run only once. After you have run this node to generate the YAML calibration file, the second node uses that file to apply the calibration to an uncalibrated IMU topic to produce a calibrated IMU topic.

Nodes

do_calib

Computes the accelerometer calibration parameters. It should be run directly with a rosrun in a terminal rather than from a launch file, since it requires keyboard input. After receiving the first IMU message, the node will prompt you to hold the IMU in a certain orientation and then press Enter to record measurements. After all 6 orientations are complete, the node will compute the calibration parameters and write them to the specified YAML file.

The underlying algorithm is a least-squares calibration approach based on and similar to that described in STMicroeletronics Application Note AN4508. Due to the nature of the algorithm, obtaining a good calibration requires fairly accurate positioning of the IMU along each of its axes.

Topics

Subscribed Topics
  • imu (sensor_msgs/Imu)
    The raw, uncalibrated IMU measurements

Parameters

  • ~calib_file (string, default: "imu_calib.yaml")
    The file to which the calibration parameters will be written
  • ~measurements (int, default: 500)
    The number of measurements to collect for each orientation
  • ~reference_acceleration (double, default: 9.80665)
    The expected acceleration due to gravity

apply_calib

Applies the accelerometer calibration parameters computed by the do_calib node. Also optionally (enabled by default) computes the gyro biases at startup and subtracts them off.

Topics

Subscribed Topics
  • raw (sensor_msgs/Imu)
    The raw, uncalibrated IMU measurements
Published Topics
  • corrected (sensor_msgs/Imu)
    The corrected, calibrated IMU measurements

Parameters

  • ~calib_file (string, default: "imu_calib.yaml")
    The file from which to read the calibration parameters
  • ~calibrate_gyros (bool, default: true)
    Whether to compute gyro biases at startup and subsequently subtract them off
  • ~gyro_calib_samples (int, default: 100)
    The number of measurements to use for computing the gyro biases

About

ROS package for computing and applying IMU calibration parameters

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published