Device support request - Elko 316 GLED RF dimmer #2497

Closed
uphillbattle opened this issue Feb 27, 2020 · 6 comments
Closed

Device support request - Elko 316 GLED RF dimmer #2497

uphillbattle opened this issue Feb 27, 2020 · 6 comments

Comments

@uphillbattle
Copy link

https://proff.elko.no/getfile.php/13124115/produkter/doc/EKO05821/Datasheet4523410.pdf

This dimmer can be paired and controlled using the ConBee stick.

Pairing is a pain - takes many tries - but eventually works.

Controlling the dimmer works, but setting the brightness at the same time as switching on or off does not work. For example, if the dimmer is off, it does not turn on if you set the brightness (to, for example, 50 %). So, if it is off, you first have to switch it on, then set the brightness.

Node info:
image

Clusters:
image

Basic cluster:
image

Level Control cluster:
image

@ebaauw
Copy link
Collaborator

ebaauw commented Feb 27, 2020

Most likely, the dimmer’s firmware doesn’t support Move to Level with On/Off. See #2475.

@uphillbattle
Copy link
Author

uphillbattle commented Feb 27, 2020

Yes, I belive that's the case. I read the thread you referenced #1111. Were you able to make the ConBee send on and brightness commands sequentially? If so, it could be done like this for the Elko dimmer (if it was supported). It's what I'm currently doing with an automation in Home Assistant, so for controlling the dimmer alone from HA, I've got it working, but I can't use "scenes" in HA since there I can't make it (the "scenes" function) send commands sequentially.

@Mimiix
Copy link
Collaborator

Mimiix commented Jun 5, 2020

@uphillbattle Is this implemented?

@uphillbattle
Copy link
Author

I'm not sure. Maybe @ebaauw knows.

@ebaauw
Copy link
Collaborator

ebaauw commented Jun 5, 2020

Were you able to make the ConBee send on and brightness commands sequentially?

Yes, but it's causing some other issues, see #2824.

@stale
Copy link

stale bot commented Jul 3, 2020

This issue has been automatically marked as stale because it has not had recent activity. It will be closed if no further activity occurs. Thank you for your contributions.