per #1835, add documentation to describe how to use PCPCombine wrappe…
Browse files Browse the repository at this point in the history
…r, including how to use [FCST/OBS]_PCP_COMBINE_CONSTANT_INIT to find files with the same initialization time
  • Loading branch information
georgemccabe committed Nov 18, 2022
1 parent 8a1d926 commit 893d987
Showing 1 changed file with 55 additions and 0 deletions.
55 changes: 55 additions & 0 deletions docs/Users_Guide/wrappers.rst
Original file line number Diff line number Diff line change
Expand Up @@ -5123,6 +5123,61 @@ The PCPCombine wrapper is a Python script that encapsulates the MET
PCPCombine tool. It provides the infrastructure to combine or extract
from files to build desired accumulations.

PCPCombine wrapper can be configured to process forecast and/or observation
data. Setting :term:`FCST_PCP_COMBINE_RUN` = True will process forecast data
and setting :term:`OBS_PCP_COMBINE_RUN` = True will process observation data.

PCPCombine wrapper can be configured to build a command for sum, add, subtract,
and derive methods using :term:`FCST_PCP_COMBINE_METHOD` and/or
:term:`OBS_PCP_COMBINE_METHOD`. Each method executes logic to gather the
desired input files to build the command based on specific examples.

Accumulations
^^^^^^^^^^^^^

The desired accumulation to build is defined using
:term:`FCST_PCP_COMBINE_OUTPUT_ACCUM` or :term:`OBS_PCP_COMBINE_OUTPUT_ACCUM`.
The default units are hours unless otherwise specified.
The output field name can be set explicitly using
:term:`FCST_PCP_COMBINE_OUTPUT_NAME` or :term:`OBS_PCP_COMBINE_OUTPUT_NAME`.

For ADD and DERIVE methods, the input accumulation(s) can be specified using
:term:`FCST_PCP_COMBINE_INPUT_ACCUMS` or :term:`OBS_PCP_COMBINE_INPUT_ACCUMS`.
The default units are hours unless otherwise specified.
This can be a list of accumulation amounts in order of preference.
If the remaining accumulation needed to build the desired accumulation is
less than the first accumulation, then the next value in the list will be used.
The name and level of the field to read for each input accumulation can be
specified with
:term:`FCST_PCP_COMBINE_INPUT_NAMES`/:term:`FCST_PCP_COMBINE_INPUT_LEVELS` or
:term:`OBS_PCP_COMBINE_INPUT_NAMES`/:term:`OBS_PCP_COMBINE_INPUT_LEVELS`.
These lists must be the same length as
:term:`FCST_PCP_COMBINE_INPUT_ACCUMS` or :term:`OBS_PCP_COMBINE_INPUT_ACCUMS`.

Constant Initialization Time
^^^^^^^^^^^^^^^^^^^^^^^^^^^^

For ADD and DERIVE methods, :term:`FCST_PCP_COMBINE_CONSTANT_INIT` or
:term:`OBS_PCP_COMBINE_CONSTANT_INIT` can be set to **True** to gather input
files that all contain the same initialization time.


User-Defined Commands
^^^^^^^^^^^^^^^^^^^^^

There are many ways to utilize PCPCombine that may not align with the logic
used to gather files. If this is the case, then the method can be set to
**USER_DEFINED** and the explicit command arguments can be specified using
:term:`FCST_PCP_COMBINE_COMMAND` or :term:`OBS_PCP_COMBINE_COMMAND`.
Other METplus configuration variables and filename template tags can be
referenced in the explicit command. Note that the path to the pcp_combine
executable and the output path should not be included in the command value.
The output path is controlled by
:term:`FCST_PCP_COMBINE_INPUT_TEMPLATE`/:term:`FCST_PCP_COMBINE_INPUT_DIR` or
:term:`OBS_PCP_COMBINE_INPUT_TEMPLATE`/:term:`OBS_PCP_COMBINE_INPUT_DIR` and
will automatically be added to the end of the command.


METplus Configuration
---------------------

Expand Down