modio is a generic tool for read and write modbus registers. modio stands for (mod)bus
(i)nput (o)utput. It supports modbus RTU and modbus TCP connections. Modbus register
data can be presented in binary, decimal, hexadecimal and ascii format. Additional device and
register information can be supplied as external structured configuration files which can be
used to format and enrich the modbus printout data.
-
For the description of modio tool visit
https://github.com/dtsecon/modio -
To submit bug reports and feature suggestions, or to track changes visit:
https://github.com/dtsecon/modio
modio requires the following external libraries in order get compiled and run:
- libconfig, a simple library for processing structured configuration files
(https://hyperrealm.github.io/libconfig/) - libmodbus, a free software library to send/receive data according to the Modbus
protocol. This library is written in C and supports RTU (serial) and TCP (Ethernet)
communications. (https://libmodbus.org/) - hashmap, a generic C hashmap implementation with light-weight pre-processor macros
which provide a templated type-safe interface (https://github.com/tidwall/hashmap.c)
-
libcofnig. You can either install libconfig as distribution packages...
iibconfig9
libconfig-dev
...or download compile and install from sources:
git clone https://github.com/hyperrealm/libconfig
- download the sourcecd libconfig
autoreconf
./configure
make
sudo make install
for more details read:
https://github.com/hyperrealm/libconfig/blob/master/INSTALL
-
libmodbus. The latest stable release is available in many Linux distributions.
You can also download, compile and install from the source code:git clone https://github.com/stephane/libmodbus
- download the sourcecd libmodbus
./autogen.sh
./configure --prefix=/usr/local/
- defalut installationprefix=/usr
make
sudo make install
-
hashmap. To build and install on your host system, follow these easy steps:
git clone https://github.com/DavidLeeds/hashmap.git
- download the sourcemkdir build-hashmap && cd build-hashmap
- create a build directory outside the source treecmake ../hashmap
- run CMake to setup the buildmake
- compile the codemake test
- run the unit tests (if enabled)sudo make install
- OPTIONAL install the library on this system
-
modio. Build and install modio:
git clone https://github.com/dtsecon/modio
- download the sourcecd modio
./autogen.sh
./configure
- default installation prefix=/usr/localmake
make install
modio tool can read or write directly to a modbus register either defined as a register number
or address. Register access info is given via a command line switch --reg (-g)
. The register
data read from a device are printed on the shell standard output along with additional register
meta data.
~$ modio -p192.168.2.104 -g35021 -o2 -r
reg: 35021 name: deviceUpTime address: 0x0003139c value: 103598s
Device and register meta-data are not required for modio to read or write
a register.
~$ modio -p192.168.2.104 -a -g5020 -t2 -r -l2 -f6
reg: 5020 address: 0x0003139c value: 105214
Register meta-data info is organized into configuration files with each file representing a specific
device register list. Device Configration files are organized into two sections. The first section
specifies the device meta-data...
device =
{
manfc = "MOXA";
type = "RIO";
model = "IoLogik E1200";
zba = 1;
};
...while the second one specifies the registers' meta-data.
regs =
(
{
num = 35041;
addr = 0x0;
len = 30;
type = 2;
name = "deviceName";
descr = "";
range = "";
scale = 1.0;
engu = "";
access = "R";
print = 3;
},
{
num = 35021;
addr = 0x0;
type = 2;
len = 2;
name = "deviceUpTime";
descr = "";
range = "";
scale = 1.0;
engu = "s";
access = "R";
print = 6;
}
)
The register meta-data fields are specified below:
FIELD DESCRIPTION TYPE
num: register number (integer)
addr: register address (integer preferable in hex format)
type: register type (0:COIL, 1:INPUT_BIT, 2:INPUT_REG, 3:HOLDING_REG)
name: register name (string)
descr: register description (string)
range: register value range (string)
scale: register value scale factor (float)
engu: register value engineering unit (string)
access: register access (string) e.g: R|W|RW
print: register print format (0:BIN 1:HEX 2:DEC 3:ASC 4:BFD 5:BFX 6:HLO)
- All fields must be defined and honor the field type
scale
is used by modio to calculate the register value when-o <id>
switch is usedtype
is used by modio to select register access type without-t <type>
switchprint
is used by modio to print register as:- binary (BIN),
- hex (HEX),
- decimal (DEC),
- ASCII (ASC),
- byte decimal (BFD),
- byte hex (BFX),
- high low word (HLO)
modio scans the directories /usr/local/share/modio
and $HOME/.modio
for device register
configuration files at run time. All verified configuration files distributed with the modio
source are copied in /usr/local/share/modio
directory. The user can also create and add more
device configuration files under $HOME/.modio
directory, following the aforementioned syntax
rules.
Usage: modio [OPTIONS]...
--(p)ort <val> device port can be either a file or an IP address (default: /dev/ttyUSB0)
example: /dev/tty<PORT>, 192.0.12.3, 192.168.1.2:1502 (default TCP port 502)
--baud <val> serial port baud rate (default 9600)
--parity <val> serial port parity (N:none O:odd E:even M:mark default N)
--sbit <val> serial port stop bit (default 1)
--dbit <val> serial port data bits (default 8)
--dev_(i)d <val> modbus slave device id (default 1)
--(z)ero disable modbus zero based addressing (address = register - type offset)
example: address = 35021(reg_num) - 30000(type_offset) = 5021
--re(g) <val>| register number (default number 0x1)
<address>| register address (default 0) if -a has been specified
<v,v,v,v> comma separated values of addresses or registers e.g. -a0x40032,0x40101,0x4078
example: modio -p/dev/ttyS0 -a0x40032,0x40101,0x4078 -r -t3
--(r)ead read data from memory
--(w)rite <val> write data to address or register
--(l)en <val> length of read count from address or register (default 1)
length is defined in words or registers and word size depends on register type
example: modio -p/dev/ttyS0 -a0x40078 -l3 -r -t3 reads 3 16bit registers
starting from address 0x40078
--reg_(a)ddress read (write) data from (to) register address
--reg_(t)ype <val> register type (0:COIL 1:INPUT_BIT 2:INPUT_REG 3:HOLDING, default 0)
--(f)ormat <val> format print output (default value 2)
0: bin
1: hex
2: dec
3: ascii
4: dot ('.') separated bytes as dec
5: dot ('.') separated bytes as hex
6: high/low register words as dec
--reg_inf(o) [id] print registers' meta data info of device id, if it is available
--(d)ev_info [id] id is optional, if defined print registers' info for selected device otherwise
print list of supported devices
--r(e)ad_all <id> read all registers' from device with <id> in the list of supported devices
--debug <val> print debug messages
--(h)elp print usage
Examples:
- Print the list with supported devices:
~$ modio -d
Supported devices:
NUM TYPE MANUFACTURER MODEL REGS
1 UPS ADELE CBI2801224A 27
2 RIO MOXA IoLogik E1200 24
- Print the list of registers of supported device:
~$ modio -d2
MOXA IoLogik E1200 RIO
NUM ADDRESS NAME DESCRIPTION LEN RANGE SCALE ENGU ACC
35041 0x313b0 deviceName 30 1.00 R
35021 0x3139c deviceUpTime 2 1.00 s R
35030 0x313a5 firmwareVersion 2 1.00 R
35032 0x313a7 firmwareBuildDate 2 1.00 R
35028 0x313a3 lanIp 2 1.00 R
35025 0x313a0 lanMac 3 1.00 R
35001 0x31388 modelName 10 1.00 R
4145 0x1030 watchdogAlarmFlag 1 1.00 R/W
11001 0x103e8 DI_counterOverflowFlag 0:Normal,1:Overflow 16 1.00 R
289 0x120 DI_counterOverflowFlagClear 16 1.00 R/W
273 0x110 DI_counterReset 1: reset to initial value 16 1.00 R/W
257 0x100 DI_counterStatus 0:STOP,1:START 16 1.00 R
17 0x30010 DI_counterValue high/low word 32 1.00 R
1 0x10000 DI_status 0:OFF,1:ON 16 1.00 R
...
- Read starting from modbus register number 35041 on modbus TCP server with ip address 192.168.2.104,
a 30 words long buffer and print the results as an ascii string:
~$ modio -p192.168.2.104 -g35041 -r -l30 -f3
reg: 35041 address: 0x000313b0 value: iologik-E1212
- Read the modbus INPUT register address 5020 on modbus TCP server with ip address 192.168.2.104, and print
the results using register meta-data info from device with id 2:
~$ modio -p192.168.2.104 -a -g5020 -t2 -r -o2
reg: 35021 name: deviceUpTime address: 0x0003139c value: 111048s
- Read starting from modbus INPUT register address 5024 on modbus TCP server with ip address 192.168.2.104, and print
the results as dot ('.') separated bytes in hex format:
~$ modio -p192.168.2.104 -a -g5024 -t2 -r -l3 -f5
reg: 5024 address: 0x000313a0 value: 0.90.e8.8b.2d.5a
- Read all registers from modbus server with ip address 192.168.2.104, using register meta-data info from
device with id 2:
~$ modio -p192.168.2.104 -e2
RIO MOXA IoLogik E1200:
REG NAME ADDRESS VALUE
35041 deviceName 0x000313b0 iologik-E1212
35021 deviceUpTime 0x0003139c 111461.00s
35030 firmwareVersion 0x000313a5 3.1.0.0
35032 firmwareBuildDate 0x000313a7 319489551.00
35028 lanIp 0x000313a3 192.168.2.104
35025 lanMac 0x000313a0 0.90.e8.8b.2d.5a
35001 modelName 0x00031388 E1212
04145 watchdogAlarmFlag 0x00001030 0
11001 DI_counterOverflowFlag 0x000103e8 0
11002 DI_counterOverflowFlag 0x000103e9 0
11003 DI_counterOverflowFlag 0x000103ea 0
11004 DI_counterOverflowFlag 0x000103eb 0
11005 DI_counterOverflowFlag 0x000103ec 0
- Read eight registers starting from modbus COIL register number 1 from modbus server with ip address 192.168.2.104
~$ modio -p192.168.2.104 -g1 -l8 -r
reg: 00001 address: 0x00000000 value: 0
reg: 00002 address: 0x00000001 value: 0
reg: 00003 address: 0x00000002 value: 0
reg: 00004 address: 0x00000003 value: 0
reg: 00005 address: 0x00000004 value: 0
reg: 00006 address: 0x00000005 value: 0
reg: 00007 address: 0x00000006 value: 0
reg: 00008 address: 0x00000007 value: 0
- Write eight registers at modbus server with ip address 192.168.2.104, starting from modbus COIL register number 1 with
the value 1 and then read them all:
~$ modio -p192.168.2.104 -g1 -l8 -w1 -r
reg: 00001 address: 0x00000000 value: 1
reg: 00002 address: 0x00000001 value: 1
reg: 00003 address: 0x00000002 value: 1
reg: 00004 address: 0x00000003 value: 1
reg: 00005 address: 0x00000004 value: 1
reg: 00006 address: 0x00000005 value: 1
reg: 00007 address: 0x00000006 value: 1
reg: 00008 address: 0x00000007 value: 1