RouDi doesn't start after an abnormal termination #113

Closed
elBoberido opened this issue May 26, 2020 · 0 comments · Fixed by #114
Closed

RouDi doesn't start after an abnormal termination #113

elBoberido opened this issue May 26, 2020 · 0 comments · Fixed by #114
Assignees
Labels
bug Something isn't working

Comments

@elBoberido
Copy link
Member

Required information

Operating system:
POSIX

Compiler version:
all

Observed result or behaviour:
RouDi doesn't start after an abnormal termination, e.g. "kill -9"

Expected result or behaviour:
RouDi should restart after an abnormal termination

Conditions where it occurred / Performed steps:

  • start RouDi and kill it with "kill -9"
  • try restart RouDi
@elBoberido elBoberido added the bug Something isn't working label May 26, 2020
@elBoberido elBoberido self-assigned this May 26, 2020
elBoberido added a commit to elBoberido/iceoryx that referenced this issue May 26, 2020
…maly

Signed-off-by: Kraus Mathias (CC-AD/ESW1) <mathias.kraus2@de.bosch.com>
@elBoberido elBoberido linked a pull request May 26, 2020 that will close this issue
elBoberido added a commit that referenced this issue May 26, 2020
…p-at-startup-after-anomaly

iox-#113 cleanup shared memory at restart after an anomaly