Fix #1147 - Exhaust temperature always zero on GB125/MC110/RC310 #1150

Merged
merged 3 commits into from Apr 2, 2023
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Jump to
Jump to file
Failed to load files.
Diff view
Diff view
4 changes: 3 additions & 1 deletion src/devices/boiler.cpp
Expand Up @@ -1032,6 +1032,8 @@ void Boiler::process_UBAMonitorFastPlus(std::shared_ptr<const Telegram> telegram
//has_update(telegram, temperatur_, 13); // unknown temperature
//has_update(telegram, temperatur_, 27); // unknown temperature

has_update(telegram, exhaustTemp_, 31);

// read 3 char service code / installation status as appears on the display
if ((telegram->message_length > 3) && (telegram->offset == 0)) {
char serviceCode[4] = {0};
Expand Down Expand Up @@ -1096,7 +1098,7 @@ void Boiler::process_UBAMonitorSlowPlus(std::shared_ptr<const Telegram> telegram
has_bitupdate(telegram, ignWork_, 2, 3);
has_bitupdate(telegram, heatingPump_, 2, 5);
has_bitupdate(telegram, wwCirc_, 2, 7);
has_update(telegram, exhaustTemp_, 6);
// has_update(telegram, exhaustTemp_, 6); // Disabled until verified as valid location, see #1147.
has_update(telegram, burnStarts_, 10, 3); // force to 3 bytes
has_update(telegram, burnWorkMin_, 13, 3); // force to 3 bytes
has_update(telegram, burn2WorkMin_, 16, 3); // force to 3 bytes
Expand Down