bad imu sample rate ? #667

Open
mahammadirfan opened this issue Feb 2, 2024 · 2 comments
Open

bad imu sample rate ? #667

mahammadirfan opened this issue Feb 2, 2024 · 2 comments
Labels
user-platform User has trouble running on their own dataset

Comments

@mahammadirfan
Copy link

Hi,
I am doing cam-imu calibration using dji based m300 drone imu and its front stereo camera, these topics are subscribed from dji osdk ros to onboard nvidia nx board...where i recorded the bag files for kalibr. the imu publishes at 200 hz and both left-right cameras at 20 hz. i tried may times this calibration but not able to implement it with any of the stereo-inertial slam. I observed my imu sample rate is bad......is there anything i can do to improve the kalibr results ?
Screenshot from 2024-02-02 18-22-05

Thanks

@mahammadirfan
Copy link
Author

mahammadirfan commented Feb 2, 2024

200hz-imu-results-imucam.txt
this is my kalib imu-cam calibration txt file.

@goldbattle goldbattle added the user-platform User has trouble running on their own dataset label Mar 25, 2024
@goldbattle
Copy link
Collaborator

Your IMU is not something that is usable. You need to fix the driver to address the problem otherwise there is no hope to do calibration or even use the IMU in any down stream application.