# hash tag is a comment, any line begin with a # doesn't affect the behavior
# Port setting. Determine which sensor is actually plugged into the port
# Valid values: [ammonium, nitrate, none]
ports:
analog1: ammonium
analog2: nitrate
# to apply the formula "E = Eo + m(ln C)", two calibration param required
# details see
# https://github.com/VernierSoftwareTechnology/arduino/blob/master/VernierBNC/VernierBNC.ino
calibration:
ammonium:
Eo: 170.82
m: 25.743
nitrate:
Eo: 170.82
m: 25.743
# sample rate. Three levels of sample rates is allowed. Minimum interval is 1 second.
# enter 0 to disable the level
rate:
level1: 5
level2: 60
level3: 0
# output folder:
# directory: '' # set an empty string to store csv in the same folder as the application root folder
# Or set the absolute path of the destination. NO TRAILING '\'
directory: 'C:\Users\fredw\Desktop\new_build'