16 changes: 12 additions & 4 deletions src/Core/hco_calc_mod.F90
Expand Up @@ -409,9 +409,12 @@ SUBROUTINE HCO_CalcEmis( HcoState, UseConc, RC )
! Add category emissions to diagnostics at category level
! (only if defined in the diagnostics list).
IF ( Diagn_AutoFillLevelDefined(HcoState%Diagn,3) .AND. DoDiagn ) THEN
! Bug fix: Make sure to pass COL=-1 to ensure all HEMCO diagnostics
! are updated, including those manually defined in other models
! (mps, 11/30/21)
CALL Diagn_Update( HcoState, ExtNr=ExtNr, &
Cat=PrevCat, Hier=-1, HcoID=PrevSpc, &
AutoFill=1, Array3D=CatFlx, COL=HcoState%Diagn%HcoDiagnIDDefault, RC=RC )
AutoFill=1, Array3D=CatFlx, COL=-1, RC=RC )
IF ( RC /= HCO_SUCCESS ) RETURN
#ifdef ADJOINT
IF (HcoState%IsAdjoint) THEN
Expand Down Expand Up @@ -460,9 +463,12 @@ SUBROUTINE HCO_CalcEmis( HcoState, UseConc, RC )
! The same diagnostics may be updated multiple times during
! the same time step, continuously adding emissions to it.
IF ( Diagn_AutoFillLevelDefined(HcoState%Diagn,2) .AND. DoDiagn ) THEN
! Bug fix: Make sure to pass COL=-1 to ensure all HEMCO diagnostics
! are updated, including those manually defined in other models
! (mps, 11/30/21)
CALL Diagn_Update( HcoState, ExtNr=ExtNr, &
Cat=-1, Hier=-1, HcoID=PrevSpc, &
AutoFill=1,Array3D=SpcFlx, COL=HcoState%Diagn%HcoDiagnIDDefault, RC=RC )
AutoFill=1,Array3D=SpcFlx, COL=-1, RC=RC )
IF ( RC /= HCO_SUCCESS ) RETURN
#ifdef ADJOINT
IF (HcoState%IsAdjoint) THEN
Expand Down Expand Up @@ -627,11 +633,13 @@ SUBROUTINE HCO_CalcEmis( HcoState, UseConc, RC )
! Now remove PosOnly flag. TmpFlx is initialized to zero, so it's
! ok to keep negative values (ckeller, 7/12/15).
IF ( Diagn_AutoFillLevelDefined(HcoState%Diagn,4) .AND. DoDiagn ) THEN
! Bug fix: Make sure to pass COL=-1 to ensure all HEMCO diagnostics
! are updated, including those manually defined in other models
! (mps, 11/30/21)
CALL Diagn_Update( HcoState, ExtNr=ExtNr, &
Cat=ThisCat,Hier=ThisHir, HcoID=ThisSpc, &
!AutoFill=1, Array3D=TmpFlx, PosOnly=.TRUE.,&
AutoFill=1, Array3D=TmpFlx, &
COL=HcoState%Diagn%HcoDiagnIDDefault, RC=RC )
COL=-1, RC=RC )
IF ( RC /= HCO_SUCCESS ) RETURN