Notifications
You must be signed in to change notification settings - Fork 30
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Feature Request: Arm & Disarm without code #51
Comments
I'll second this request as my alarm system does not have a code |
Let me take a look! |
I had same issue where alarm control panel would popup a keypad to enter code even if I had unset the "code" key in the configuration.yaml. I managed to set code_format to null by adding it in my customize.yaml file. Here is an excerpt of my customize.yaml file: alarm_control_panel.name_of_my_entity: Cheers, |
Hi @jpg1961 Setting up code_format to null in the customize.yaml file works like a charm, thank you! Best regards. |
Hi @DNKROZ, Cheers, |
Sorry, I have been unable to reproduce this. I'm on 2.0.0.2, can someone tell me how to remove the keypad so I don't need to input a code? |
This should be working since a few releases ago |
Hi, first and foremost thank you for this custom integration, without it the Securitas alarm system lacks... a lot.
I have also installed a custom alarm panel with the "Alarmo" custom component, and also a Visonic alarm system with another custom integration, both integrations allow the arming and disarming of each system without the need to enter any codes on the keypad.
Since the default "code_disarm_required" was "false" I commented out the code option in the configuration file (code: !secret securitas_direct_code) to have the code value empty and, surprisingly .... it works! , however the "code_format" attribute is still set to "number", so the keypad still pops up in the alarm panel when trying to arm or disarm, the other integrations have this set to "null" and thus they don't show the keypad.
I've modified the alarm_control_panel.py file from the component to return a None value for the "code_format" function, however I'm not a developer and can't go much further.
Is there a way to modify this integration to return None:
return None
Instead:
return alarm.FORMAT_NUMBER
in the event the code variable from the configuration is not set?
My solution is very crude and temporary and I would very much like to have this feature merged into the main version to be able to arm/disarm every alarm panel with a button click since I'm the only one that has access to my HA instance.
Thanks in advance, best regards.
The text was updated successfully, but these errors were encountered: