Skip to content

Commit

Permalink
Pandoc does support citation locators, manubot not
Browse files Browse the repository at this point in the history
It *does* support them, but they are not shown with the default CSL: manubot/rootstock#362 (comment)
  • Loading branch information
habi committed Nov 3, 2020
1 parent c161a78 commit b615a48
Showing 1 changed file with 2 additions and 2 deletions.
4 changes: 2 additions & 2 deletions content/04.materials.methods.md
Expand Up @@ -11,11 +11,11 @@ Afterwards, the teeth were placed for one hour in a 3% hydrogen peroxide ultraso

### Micro-CT-based morphological analysis

The 104 samples were imaged on a [Bruker SkyScan 1272 @https://www.bruker.com/products/microtomography/micro-ct-for-sample-scanning/skyscan-1272/overview.html] high-resolution micro-CT machine (Control software version 1.1.19, [Bruker microCT](https://bruker-microct.com/), Kontich, Belgium).
The 104 samples were imaged on a [Bruker SkyScan 1272](https://www.bruker.com/products/microtomography/micro-ct-for-sample-scanning/skyscan-1272/overview.html) high-resolution micro-CT machine (Control software version 1.1.19, [Bruker microCT](https://www.bruker.com/products/microtomography.html), Kontich, Belgium).
To facilitate the scanning of this large batch of samples, we used the automatic sample changer to enable us to scan batches of 16 teeth without any intervention.
In addition to the sample changer, the machine is equipped with a Hamamatsu L11871\_20 X-ray source and a XIMEA xiRAY16 camera.
We used a custom-made sample-holder to scan the teeth on the sample changer.
The sample holder was 3D-printed on a [Form 2 @https://formlabs.com/3d-printers/form-2/] desktop stereolithography printer ([Formlabs](https://formlabs.com/), Somerville, Massachusetts, USA) and is freely available online (https://git.io/JJbAZ) as part of a library of sample holders [@doi:10.5281/zenodo.2587555.].
The sample holder was 3D-printed on a [Form 2](https://formlabs.com/3d-printers/form-2/) desktop stereolithography printer ([Formlabs](https://formlabs.com/), Somerville, Massachusetts, USA) and is freely available online (https://git.io/JJbAZ) as part of a library of sample holders [@doi:10.5281/zenodo.2587555.].
The X-ray source was set to a tube voltage of 80.0 kV and a tube current of 125.0 µA, the x-ray spectrum was filtered by 1mm of Aluminium prior to incidence onto the sample. For each sample, depending on the sample height, we recorded a set of either 4 or 5 stacked scans overlapping its height.
Each stack was recorded with 482 TIFF projections of 1632 x 1092 pixels at every 0.4° over a 180° sample rotation.
Every single projection was exposed for 950 ms and 3 projections were averaged to greatly reduce image noise.
Expand Down

0 comments on commit b615a48

Please sign in to comment.