Skip to content

code to calibrate the internal parameters of spinning lidar sensors

License

Notifications You must be signed in to change notification settings

halismai/calidar

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

49 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

CALIDAR

Code for automated calibration of spinning lidar internal parameters.

Installation

Code relies on Matlab for optimization (requires Matlab Optimization Toolbox). Other depedencies include:

NOTE: nanoflann can be optional. Edit utils/@KdTree/KdTree constructor and set obj.use_nanoflann = false we recommended using nanoflann.

For question, comments, or bug reports please contact:

Hatem Alismail <halismai @ cs.cmu.edu>

Usage

Code was designed to accomodate various sensor configurations. In particular, code is not tied to a specific coordinate convention.

For an example see the file example/run_example.m, which contains:

opts = struct('actuation_func', @example_sensor.actuate_split, ...
  'p2h', @example_model.p2h, ...
  'h2p', @example_model.h2p, ...
  'compute_delta_params', @example_model.compute_delta_params, ...
  'H_init', eye(4), ...
  'do_show', true, ...
  'max_outer_iters', 10);

This struct specifies options to the calibration routine. Most important fields:

  • actuation_func a function supplied by the user to perform actuation of the lidar sensing assembly

  • p2h Parameters to Homogenous transformation. Takes a vector of parameters and converts it into a 4x4 homogenous transformation matrix.

  • h2p Homogenous transformation matrix to Parameters vector. Takes a 4x4 matrix and converts back to a vector of optimization parameters.

  • H_init User supplied initializing for the calibration parameters (4x4 matrix). This is required if the initial offsets are large. The value need not be accurate and usually eye-balling, or nominal values from a CAD model will suffice.

There are other options fully documented in calibration/private/verify_options.m

See the implementation of example_sensor in +example_sensor and +example_model. The implementation is put into a matlab package so that other sensors can share the same internal function names.

For the example sensor, data is stored in an ascii CSV file. Your data can be stored in any format if you provide the I/O routines.

Recommendations for data collection

  • In order to calibration the lidar you need at least one full revolution (360 degrees) scan. More revolutions is better. We usually collect between 2-4.

  • There are no strict restrictions on the data collection environment. But, the environment must have enough 3D structure to constrain the full degrees of freedom (DOF) of the sensing assembly.

    An ideal data collection location would be a large room with several planes of different directions.

    A bad data collection location would be scanning the floor of a room. A single plane direction does not constraint the full DOF.

  • Speed/acceleration rate of the spinning motor does not affect the calibration significantly (in fact calibration parameters are indepdent of motor configuration). However, the spinning speed must be sufficiently slow to allow extraction of normals.

    If the lidar spins fast relative to the environment, scans might cluster along lines without enough constrains to extract normals.

Please see references below for more details

Citation

If you use this software please cite:

  • H. Alismail, and B. Browning, "Automatic Calibration of Spinning Actuated Lidar Internal Parameters." Journal of Field Robotics. 2014

BibTex entry:

@article{ROB:ROB21543,
  author = {Alismail, Hatem and Browning, Brett},
  title = {Automatic Calibration of Spinning Actuated Lidar Internal Parameters},
  journal = {Journal of Field Robotics},
  issn = {1556-4967},
  url = {http://dx.doi.org/10.1002/rob.21543},
  doi = {10.1002/rob.21543},
  pages = {n/a--n/a},
  year = {2014},
  }

or

  • H. Alismail, L.D. Baker, and B. Browning, "Automatic Calibration of a Range Sensor and Camera System." 3DIMPVT, 2012.

Bib entry:

@INPROCEEDINGS{6375006,
author={Alismail, H. and Baker, L.D. and Browning, B.},
booktitle={3D Imaging, Modeling, Processing, Visualization and Transmission (3DIMPVT), 2012 Second International Conference on},
title={Automatic Calibration of a Range Sensor and Camera System},
year={2012},
month={Oct},
pages={286-292},
doi={10.1109/3DIMPVT.2012.52}}