cold-end

Firmware for ColdEND controller supporting various displays

Installation and configuration:

  1. Download and import the following libraries depending on your displays:

    SSD1306 https://github.com/adafruit/Adafruit-GFX-Library https://github.com/adafruit/Adafruit_SSD1306

    SH1106 https://github.com/adafruit/Adafruit-GFX-Library https://github.com/wonho-maker/Adafruit_SH1106

    HT16K33 https://github.com/adafruit/Adafruit_LED_Backpack

    LCD 16x2 or 16x4 https://github.com/fdebrabander/Arduino-LiquidCrystal-I2C-library

  2. Uncomment (define) the appropriate display in config.h. Note that only one type of display at one time is allowed so dont' forget to comment the other ones. For 7 segment LED displays, don't forget to jumper different I2C addresses for both displays and enter these values in config.h ("LED1_ADD" and "LED2_ADD").

  3. Uncomment (define) "momentary_switch" if you want to use monentary switches. Required library: https://github.com/thomasfredericks/Bounce2 For normal switches leave "momentary_switch" commented.

  4. Uncomment (define) "drain_system" if you want to have the option to drain the coolant pump and pipes anytime. For draining the system, set the coolant to 0 ml/h and push the fast mode switch.

  5. Flash your ColdEND controller, vent the system and try the coolant potentiometer range. If your coolant output is too high and you have already set your microsteps to maximum, decrease "max_flow_rate" and reflash the ColdEND controller. The table below shows you how values and stepper RPM correlate.

  6. Make sure that the coolant knob is fully turned clockwise for maximum lubrication and turn the spit knob fully counterclockwise to deactivate spit mode. Meter your lubrication output over 10 minutes and multiply the value by 6 to get the maximum quantity in milliliter per hour.

  7. Edit "max_ml_per_hour" in config.h to the correct value and reflash your ColdEND.

Value Frequency RPM
500000 1 Hz 0,0185 rpm
250000 2 Hz 0,0370 rpm
100000 5 Hz 0,093 rpm
50000 10 Hz 0,187 rpm
25000 20 Hz 0,375 rpm
12500 40 Hz 0,750 rpm
6250 80 Hz 1,500 rpm
5000 100 Hz 1,875 rpm
3125 160 Hz 3,000 rpm
1500 333 Hz 6,243 rpm
1000 500 Hz 9,250 rpm
500 1000 Hz 18,500 rpm
250 2000 Hz 37,000 rpm
125 4000 Hz 74,000 rpm
100 5000 Hz 93,750 rpm

ATTENTION: ColdEND PUMPBoard PRO requires firmware v1.7 or higher! Dont' forget to uncomment the Board.

ATTENTION: Up from v1.3, https://github.com/PaulStoffregen/TimerOne library is required!

NOTE: If momentary switches are defined, https://github.com/thomasfredericks/Bounce2 library is required.

NOTE: If spit mode at times does not start or any of your switches seem to work not properly, it is most likely that they are bouncing. In this case, increase "switch_debounce" slightly.

HISTORY:

  • v1.9: Added support for 16x2 and 16x4 LCD panel with I2C adaptor. Added function to drain coolant system with fast mode button (reversed flow direction when coolant is set to 0)

  • v1.8: Air switch input can now be used for external mist control. This can be achieved either with a relais, an external switch or directly with a 24V output pin from a MESA card when the ColdEND controller is connected to the same 24V power source

  • v1.7: Added support for 2x HT16K33 7-segment LED displays. Ready for new ColdEND PUMPBoard PRO

  • v1.6: Fixed spit mode can't be interrupted by switch

  • v1.5: Added choice between normal switches and momentary switches. When coolant is set below 1.1 ml/h, pump will now be stopped and coolant valve closed which makes air button obsolet. Fixed bouncing relais when powering on

  • v1.4: Minor fixes

  • v1.3: New motor control based on hardware timer, fast display refresh rate, countdown in spit mode and animated pump icon added by Talla83.de

  • v1.2: Choice between exponential and linear flow control and simplified calibration process. Added screen refresh delay to minimize loop interrupts by screen refreshes. Single-digits for coolant flow (exponential flow control < 10 ml/h: decimal digits)

  • v1.1: Moved all configurable parameters to config.h and added "min_ml_per_hour" for a more accurate display value

  • v1.0: Initial rewritten firmware, supporting I2C SSD1306 and SH1106 OLED displays with 128x64 px