Add sensor device class volatile_organic_compounds_parts #92973

Merged
merged 1 commit into from
May 12, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Jump to
Jump to file
Failed to load files.
Diff view
Diff view
11 changes: 11 additions & 0 deletions homeassistant/components/number/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,6 +8,7 @@
from homeassistant.backports.enum import StrEnum
from homeassistant.const import (
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
CONCENTRATION_PARTS_PER_BILLION,
CONCENTRATION_PARTS_PER_MILLION,
LIGHT_LUX,
PERCENTAGE,
Expand Down Expand Up @@ -309,6 +310,12 @@ class NumberDeviceClass(StrEnum):
Unit of measurement: `µg/m³`
"""

VOLATILE_ORGANIC_COMPOUNDS_PARTS = "volatile_organic_compounds_parts"
"""Ratio of VOC.

Unit of measurement: `ppm`, `ppb`
"""

VOLTAGE = "voltage"
"""Voltage.

Expand Down Expand Up @@ -421,6 +428,10 @@ class NumberMode(StrEnum):
NumberDeviceClass.VOLATILE_ORGANIC_COMPOUNDS: {
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER
},
NumberDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS: {
CONCENTRATION_PARTS_PER_BILLION,
CONCENTRATION_PARTS_PER_MILLION,
},
NumberDeviceClass.VOLTAGE: set(UnitOfElectricPotential),
NumberDeviceClass.VOLUME: set(UnitOfVolume),
NumberDeviceClass.VOLUME_STORAGE: set(UnitOfVolume),
Expand Down
12 changes: 12 additions & 0 deletions homeassistant/components/sensor/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -8,6 +8,7 @@
from homeassistant.backports.enum import StrEnum
from homeassistant.const import (
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER,
CONCENTRATION_PARTS_PER_BILLION,
CONCENTRATION_PARTS_PER_MILLION,
LIGHT_LUX,
PERCENTAGE,
Expand Down Expand Up @@ -347,6 +348,12 @@ class SensorDeviceClass(StrEnum):
Unit of measurement: `µg/m³`
"""

VOLATILE_ORGANIC_COMPOUNDS_PARTS = "volatile_organic_compounds_parts"
"""Ratio of VOC.

Unit of measurement: `ppm`, `ppb`
"""

VOLTAGE = "voltage"
"""Voltage.

Expand Down Expand Up @@ -523,6 +530,10 @@ class SensorStateClass(StrEnum):
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS: {
CONCENTRATION_MICROGRAMS_PER_CUBIC_METER
},
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS: {
CONCENTRATION_PARTS_PER_BILLION,
CONCENTRATION_PARTS_PER_MILLION,
},
SensorDeviceClass.VOLTAGE: set(UnitOfElectricPotential),
SensorDeviceClass.VOLUME: set(UnitOfVolume),
SensorDeviceClass.WATER: {
Expand Down Expand Up @@ -582,6 +593,7 @@ class SensorStateClass(StrEnum):
SensorDeviceClass.TEMPERATURE: {SensorStateClass.MEASUREMENT},
SensorDeviceClass.TIMESTAMP: set(),
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS: {SensorStateClass.MEASUREMENT},
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS: {SensorStateClass.MEASUREMENT},
SensorDeviceClass.VOLTAGE: {SensorStateClass.MEASUREMENT},
SensorDeviceClass.VOLUME: {
SensorStateClass.TOTAL,
Expand Down
5 changes: 5 additions & 0 deletions homeassistant/components/sensor/device_condition.py
Original file line number Diff line number Diff line change
Expand Up @@ -70,6 +70,7 @@
CONF_IS_TEMPERATURE = "is_temperature"
CONF_IS_VALUE = "is_value"
CONF_IS_VOLATILE_ORGANIC_COMPOUNDS = "is_volatile_organic_compounds"
CONF_IS_VOLATILE_ORGANIC_COMPOUNDS_PARTS = "is_volatile_organic_compounds_parts"
CONF_IS_VOLTAGE = "is_voltage"
CONF_IS_VOLUME = "is_volume"
CONF_IS_WATER = "is_water"
Expand Down Expand Up @@ -120,6 +121,9 @@
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS: [
{CONF_TYPE: CONF_IS_VOLATILE_ORGANIC_COMPOUNDS}
],
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS: [
{CONF_TYPE: CONF_IS_VOLATILE_ORGANIC_COMPOUNDS_PARTS}
],
SensorDeviceClass.VOLTAGE: [{CONF_TYPE: CONF_IS_VOLTAGE}],
SensorDeviceClass.VOLUME: [{CONF_TYPE: CONF_IS_VOLUME}],
SensorDeviceClass.VOLUME_STORAGE: [{CONF_TYPE: CONF_IS_VOLUME}],
Expand Down Expand Up @@ -173,6 +177,7 @@
CONF_IS_SULPHUR_DIOXIDE,
CONF_IS_TEMPERATURE,
CONF_IS_VOLATILE_ORGANIC_COMPOUNDS,
CONF_IS_VOLATILE_ORGANIC_COMPOUNDS_PARTS,
CONF_IS_VOLTAGE,
CONF_IS_VOLUME,
CONF_IS_WATER,
Expand Down
5 changes: 5 additions & 0 deletions homeassistant/components/sensor/device_trigger.py
Original file line number Diff line number Diff line change
Expand Up @@ -69,6 +69,7 @@
CONF_TEMPERATURE = "temperature"
CONF_VALUE = "value"
CONF_VOLATILE_ORGANIC_COMPOUNDS = "volatile_organic_compounds"
CONF_VOLATILE_ORGANIC_COMPOUNDS_PARTS = "volatile_organic_compounds_parts"
CONF_VOLTAGE = "voltage"
CONF_VOLUME = "volume"
CONF_WATER = "water"
Expand Down Expand Up @@ -119,6 +120,9 @@
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS: [
{CONF_TYPE: CONF_VOLATILE_ORGANIC_COMPOUNDS}
],
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS: [
{CONF_TYPE: CONF_VOLATILE_ORGANIC_COMPOUNDS_PARTS}
],
SensorDeviceClass.VOLTAGE: [{CONF_TYPE: CONF_VOLTAGE}],
SensorDeviceClass.VOLUME: [{CONF_TYPE: CONF_VOLUME}],
SensorDeviceClass.VOLUME_STORAGE: [{CONF_TYPE: CONF_VOLUME}],
Expand Down Expand Up @@ -173,6 +177,7 @@
CONF_SULPHUR_DIOXIDE,
CONF_TEMPERATURE,
CONF_VOLATILE_ORGANIC_COMPOUNDS,
CONF_VOLATILE_ORGANIC_COMPOUNDS_PARTS,
CONF_VOLTAGE,
CONF_VOLUME,
CONF_WATER,
Expand Down
5 changes: 5 additions & 0 deletions homeassistant/components/sensor/strings.json
Original file line number Diff line number Diff line change
Expand Up @@ -41,6 +41,7 @@
"is_temperature": "Current {entity_name} temperature",
"is_value": "Current {entity_name} value",
"is_volatile_organic_compounds": "Current {entity_name} volatile organic compounds concentration level",
"is_volatile_organic_compounds_parts": "[%key:component::sensor::device_automation::condition_type::is_volatile_organic_compounds%]",
"is_voltage": "Current {entity_name} voltage",
"is_volume": "Current {entity_name} volume",
"is_water": "Current {entity_name} water",
Expand Down Expand Up @@ -87,6 +88,7 @@
"temperature": "{entity_name} temperature changes",
"value": "{entity_name} value changes",
"volatile_organic_compounds": "{entity_name} volatile organic compounds concentration changes",
"volatile_organic_compounds_parts": "[%key:component::sensor::device_automation::trigger_type::volatile_organic_compounds%]",
"voltage": "{entity_name} voltage changes",
"volume": "{entity_name} volume changes",
"water": "{entity_name} water changes",
Expand Down Expand Up @@ -244,6 +246,9 @@
"volatile_organic_compounds": {
"name": "VOCs"
},
"volatile_organic_compounds_parts": {
"name": "[%key:component::sensor::entity_component::volatile_organic_compounds::name%]"
},
"voltage": {
"name": "Voltage"
},
Expand Down
1 change: 1 addition & 0 deletions tests/components/sensor/test_init.py
Original file line number Diff line number Diff line change
Expand Up @@ -1758,6 +1758,7 @@ async def test_non_numeric_device_class_with_unit_of_measurement(
SensorDeviceClass.SULPHUR_DIOXIDE,
SensorDeviceClass.TEMPERATURE,
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS,
SensorDeviceClass.VOLATILE_ORGANIC_COMPOUNDS_PARTS,
SensorDeviceClass.VOLTAGE,
SensorDeviceClass.VOLUME,
SensorDeviceClass.WATER,
Expand Down