Expand Up @@ -31,16 +31,17 @@ <h2 id="usage">Usage</h2>
values because OED sometimes needs to internally use a special name that is not very user friendly so the
identifier is also useful. Sites can also use this name for similar or other reasons when they want
something other than what is displayed to the user. The name of a meter must be different from any other
meter. This field will be outlined in red until a unit is selected as
meter. This field will be outlined in red until a name is input as
is shown in the figures.</li>
<li>Unit. This dropdown menu allows for the selection of the unit that the meter collects in. This is related
but different than the <a href="./graphingUnits.html">graphing unit</a> used. Some information on the meter
unit is given on the <a href="exampleDescription.html">help example</a> page. The result of
clicking this dropdown menu is shown in the following figure.</li>
<!-- Need to override the default size for most images on pages. -->
<img alt="Admin meter unit choices" src="./images/adminMeterUnitDropdown.png" style="width:249">
<p>All units of meter type will be shown and any one that is compatible with the default graphic unit can be
selected by clicking it. The compatible/selectable units will be at the top of the dropdown menu and the
<p>All units of meter type will be shown and can be
selected by clicking it if it is compatible with the default graphic unit. The compatible/selectable units
will be at the top of the dropdown menu and the
incompatible/non-selectable ones will be at the bottom in grayed out font. In the following figure, the
compatible units are in the blue Rectangle and the incompatible units are in the light blue rectangle where
the
Expand All @@ -52,12 +53,12 @@ <h2 id="usage">Usage</h2>
the default graphic unit as long as there is a
conversion that exists between them. Note that if "no unit" is selected for the default graphic unit then
every
unit is compatible with that. Meters can only collect in
unit is compatible with that (see first figure of Unit dropdown). Meters can only collect in
units of meter type and must be linked by a conversion to a regular unit for graphing. There is a choice of
"no
unit" on this menu but it is generally not used. If this is selected then the meter can collect data but
would be unusable for graphics. The default graphic unit is automatically set to "no unit" when the meter
unit is set to that value. It is mostly used internally to OED for automatically creating meters where
unit is set to that value. It is mostly used internally by OED for automatically creating meters where
the unit is not known and then the admin needs to set this unit afterward. If one needs to
select a different unit that does not have a conversion to the current unit then selecting "no unit" for the
default graphic
Expand All @@ -66,25 +67,30 @@ <h2 id="usage">Usage</h2>
<li>Default Graphic Unit. This dropdown menu allows for the selection a compatible <a
href="./graphingUnits.html">graphing unit</a>
that is used if one is not
already selected before this meter is chosen. A default graphic unit is compatible with the meter unit if a
already selected before this meter is chosen. It allows a site to automatically display a meter in its
preferred graphic unit. For example, a site might prefer to graph a meter in US $ (money) even though it
collects
in kWh. Even if the default graphic unit is the same as the meter unit it must be set separately. A default
graphic unit is compatible with the meter unit if a
conversion exists between them. As with the meter unit, the compatible/selectable units will be at the top
of the dropdown menu and the
incompatible/non-selectable ones will be at the bottom in grayed out font. Initially this menu will only
have "no unit" as compatible because that is the only
compatible unit with "no unit" as shown in the following figure.</li>
compatible unit with a "no unit" meter unit as shown in the following figure.</li>
<!-- Need to override the default size for most images on pages. -->
<img alt="Admin meter default graphic unit choices when no meter unit"
src="./images/adminMeterDguNoUnitDropdown.png" style="width:248">
<p>The dropdown menu when the meter unit is already set to Electric_Utility is shown in the following figure.
All units from Celsius and below are not compatible and grayed out.</p>
<!-- Need to override the default size for most images on pages. -->
<img alt="Admin meter unit choices" src="./images/adminMeterDguEuDropdown.png" style="width:248">
<p>This field will be outlined in red until a unit is selected as
<p>If "no unit" is selected then this meter cannot be graphed until a compatible unit is already selected. This
field will be outlined in red until a unit is selected as
is shown in the figures.</p>
<li>Updates. This dropdown menu can be "yes" or "no" (default). If "yes" and OED knows how to automatically
acquire readings from this meter then it will be done whenever the site automatically acquires readings from
meters. (See information on <a href="./adminInstallation.html">site installation</a> about automatic meter
reading acquisition.) If no then no data will automatically be acquired for this meter.</li>
reading acquisition.) If "no" then no data will automatically be acquired for this meter.</li>
<li>Displayable. This dropdown menu can be "yes" or "no" (default). "yes" indicates the meter
can be seen and graphed by any user and "no" limits the meter visibility and graphing to admins.
<li>Type. This dropdown menu allows for setting the type of a meter which is generally the vendor associated
Expand All @@ -93,53 +99,149 @@ <h2 id="usage">Usage</h2>
data
directly. If you want and can to use a meter not on this list then select "OTHER". See the page on <a
href="./adminDataAcquisition.html">data acquisition</a> for more information. Please <a
href="../../contact.html">contact us</a> if you want to use meters for that we do not yet support. This
href="../../contact.html">contact us</a> if you want to use meters that OED does not yet support. This
field will be outlined in red
until a unit is selected as
until a type is selected as
is shown in the figures.</li>
<img alt="Admin meter type choices" src="./images/adminMeterTypeDropdown.png" style="width:248">

<li>Reading Frequency.</li>
<li>URL.</li>
<li>GPS.</li>
<li>Area.</li>
<li>Meter Area Unit.</li>
<li>Reading Frequency. This defines the rate at which OED receives readings from this meter. It impacts the
<a href="./lineGraphic.html#lineQuality">quality of data seen in a line graphic</a> and the estimates of
the <a href="./export.html#exportSize">size of exported data files</a> since it is used to estimate the
number of points in the range of time requested. The standard
format is HH:MM:SS, e.g., 00:15:00 for 15 minutes, but OED can also accept other formats such as 3 hours or
4 days. The default value is the one on the <a href="./adminPreferences.html">admin preferences page</a>
that will default to 00:15:00 for 15 minutes unless changed by the admin.
</li>
<li>URL. This is the URL used when OED automatically acquires readings during <a
href="./adminDataAcquisition.html">data acquisition</a>. The value is meter type specific and shown on
the help
page about each meter. It can be left blank if not needed by this meter type.</li>
<li>GPS. This is the GPS location of the meter entered as latitude, longitude (without parentheses). It is used
when the values from
the meter are placed on a <a href="./mapGraphic.html">map graphic</a>. More information on using the best
GPS
value is given on the <a href="./adminMap.html.html">admin help page for maps</a>. If blank then there is no
GPS value and the meter cannot be placed on a map.</li>
<li>Area. A non-negative number of the area associated with the meter. It is used when <a
href="./areaNormalization.html">normalizing graphics by area</a>. It has a default value of zero
that means this meter cannot be normalized by area. The default value will be used if the input is left
blank.
This field will be outlined in red until valid value (including blank) is entered if an invalid value is
entered.</li>
<li>Meter Area Unit. This dropdown menu can have the values shown in the following figure. The usable area units
are "sq. feet" and "sq. meters". If "no unit" is selected then the field will be red if the area is non-zero
because OED needs to know the unit of the area. The default value is "no unit" and this can be used if the
area is reset back to zero so the choice is valid.</li>
<img alt="Admin meter area unit choices" src="./images/adminMeterAreaUnitDropdown.png" style="width:254">
<li>Note. This may give additional information about the meter supplied when OED created it or from the
admin. Only the first 30 characters will be shown and any additional characters in the note can be seen by
clicking the "Edit Meter" button.</li>
<li>Cumulative.</li>
<li>Cumulative Reset.</li>
<li>Cumulative Reset Start.</li>
<li>Cumulative Reset End.</li>
<li>End Only Time.</li>
<li>Reading Gap.</li>
<li>Reading Variation.</li>
<li>Reading Duplication.</li>
<li>Time Sort.</li>
<li>Start Time Stamp. This is less commonly used.</li>
<li>End Time Stamp. This is less commonly used.</li>
<li>Time Zone.</li>
<li>Reading. This is less commonly used.</li>
<li>Previous End Time Stamp.</li>
admin. Any text can be entered and it can be blank if desired.</li>
<li>Cumulative. This dropdown menu can be "yes" or "no" (default). If "yes", then the readings on this
meter increase with each successive reading and represent the total usage over time. This means that the
reading value for a reading's time range is determined by subtracting the value of the previous reading from
the current
reading. If "no", then the meter is not cumulative and each reading represents the usage for the time range
of
this reading.</li>
<li>Cumulative Reset. This dropdown menu can be "yes" or "no" (default). Some cumulative meters periodically
reset the total back to zero. If "yes" then this can happen and "no" means it does not. Whenever a reset
occurs (the current reading is
less than the previous reading) then the value for that reading is directly used. If a reset is detected and
is outside the times specified (see next two parameters) then OED will reject all readings in the current
batch supplied to OED due to
the error.</li>
<li>Cumulative Reset Start. The earliest time of each day that cumulative reset can occur. By limiting the time
that OED accepts a cumulative reset, OED is able to report issues outside that time. The input format is
HH:MM:SS.ss, e.g. 10:11:22.33, where the fractions of a second can be omitted, e.g. 12:24:36. If no value is
provided (empty text box) then the value will default to 00:00:00 which means the start of the day. The
start of the day should be used if one wants to allow a cumulative reset at any time. This
value is not used if cumulative reset is no. There
are several types of invalid time values that will produce the following errors on input when you save:<ul>
<li>Invalid times such as letters or negative values (-10:00:00 here) will produce the error: "Failed to
edit meter with message: "error: invalid input syntax for type time: "-10:00:00" with
detail undefined"</li>
<li>Times that are more than 24 hours so not within a day (24:50:00 here) will produce the error:
"Failed
to edit meter with message: "error: date/time field value out of range: "24:50:00" with
detail undefined"</li>
<li>If the reset start time is not before the reset end time (start of 10:00:01, end of 10:00:00 here)
will
produce the error (other provided meter values are included and shown here): "Failed to edit meter
with message: "error: new row for relation "meters" violates check constraint
"meter_cumulative_reset" with detail Failing row contains (121, zz, , f, f, other, null, null, zz, ,
0, f, f, 10:00:01, 10:00:00, 0, 0, 1, increasing, f, 0, 1970-01-01 00:00:00+00:00, 1970-01-01
00:00:00+00:00, 1970-01-01 00:00:00, 152, 158, none, PT15M)."</li>
</ul>
</li>
<li>Cumulative Reset End. The latest time of each day that cumulative reset can occur. Similar input, errors and
usage to Cumulative Reset Start. If no value is
provided (empty text box) then the value will default to 23:59:59.999999 meanings the end of the day. The
end of the day should be used if one wants to allow a cumulative reset at any time. This
value is not used if cumulative reset is no.</li>
<li>End Only Time. This dropdown menu can be "yes" or "no" (default). "yes" if each reading for this meter only
has an end
date/time stamp and no start time stamp meaning a reading has two values (reading value and end date/time
stamp).
"no" if it has three values for each reading (reading value, start date/time stamp and end date/time stamp).
OED
will automatically convert an end only time reading to have a start time by using the previous reading's
time stamp as is
normal for these type of reading.</li>
<li>Reading Gap. A non-negative number of how many seconds are considered normal between the end of one reading
and the start of the next reading. A value of zero (default value) indicates that there should never be a
gap in readings and they
always abut each other. OED will issue a warning each time it sees a reading that
has a gap greater than the meter allows whenever readings are acquired for this meter.</li>
<li>Reading Variation. A non-negative number of how may seconds the length of one reading can vary for the
length of the next reading (end date/time - start date/time). A value of zero (default value) indicates that
all
readings should be of the same length. OED will issue a warning each time it sees a reading that
has a length variation greater than the meter allows whenever readings are acquired for this meter.</li>
<li>Reading Duplication. A positive integer of how many times each reading is duplicated when the meter
provides values. There are some meters that give the same readings multiple times in a row. Ones that do not
should have a value of 1 (default). For example, if the value is 3 then OED reads the first reading of each
three readings and ignores the next two. If a non-integer is input then after one saves the error
message "Failed to create meter with message: "validation failed with instance.readingDuplication is not of
a
type(s) integer" will be shown. The number of duplications must be between 1 and 9. If it is outside this
range then this field will be outlined in red until a valid value is input.</li>
<li>Time Sort. This dropdown menu can be "increasing" (default) or "decreasing". If "increasing" then readings
are supplied so later ones in time are later in each batch of reading supplied to OED. If "decreasing" then
later times
come earlier in each batch of reading supplied to OED.</li>
<li>Start Time Stamp. This is less commonly used. It is the start date/time stamp of the last reading processed
in
the last batch of readings received by OED for this meter. Normally this value is automatically set by OED
each time it processes a batch of data. In unusual circumstances of manual batch loading of data into OED
this may need to be set. This value is used when the last processed reading from the last batch
is needed to determine information. This happens for end only meters and cumulative meters and also used to
generate warnings in some cases about reading variation and gap. The standard format for input is YYYY-MM-DD
HH:MM:SS, e.g., 2020-05-22 13:15:45. If no value is provided (empty text field) then the default value of
1970-01-01 00:00:00 is used and OED understands this special value as not having yet read data and will deal
with it appropriately.</li>
<li>End Time Stamp. This is less commonly used. It is the end date/time stamp of the last reading processed in
the last batch of readings received by OED for this meter. It is similar to the Start Time Stamp and has the
same default.</li>
<li>Reading. This is less commonly used. It is the reading value of the last reading processed in
the last batch of readings received by OED for this meter. It has the default value of zero.</li>
<li>Time Zone. The timezone of this meter as text. OED can accept most standard time zone names such as <a
href="https://en.wikipedia.org/wiki/List_of_tz_database_time_zones" rel="noopener noreferrer">this
Wikipedia one</a>
where the "TZ identifier" is used, e.g., Pacific/Galapagos for the Galápagos Islands. The time zone of a
meter only needs to be set if the meter readings are time zone aware. For example, eGauge meters are time
zone aware and can provide data that accounts for daylight savings. This sets the time zone for this meter
and overrides the <a href="adminPreferences.html">site
preferences</a> time zone value.
This is useful if some meters are not in the same time zone as the site default. See the <a
href="time.html">time
help page</a> for further information.</li>
<li>Previous End Time Stamp. This is less commonly used. It is similar to the End Time Stamp but for the next to
last (penultimate; one before the End Time Stamp) reading processed in
the last batch of readings received by OED for this meter. Normally this value is automatically set by OED
each time it processes a batch of data. It is only used for meters that have a time zone
and honor daylight savings such as eGauge. It is only really important for detecting when time crosses
daylight savings. It is similar to the Start Time Stamp and has the same default.</li>
</ol>

<h2 id="details">Details</h2>
<p>None</p>
</div>

<li>Meter Type: This is the type of meter as stored in OED. This information might be useful if you are looking
for a particular type of meter or to be sure it is the correct type.</li>
<li>Meter Address: This is the IP address to get data if the meter type is MAMAC. It is the address that Obvius
data came from if the meter type is Obvius.</li>
<li>Meter GPS: This is the latitude and longitude used when placing this meter on a map. You can edit the value
here. See the <a href="adminMap.html">admin map help</a> for more information on maps.</li>
<li>Meter Updates. This tells if OED tries to automatically gather this meter's data (assuming the site was
properly set up the do meter updates). At the current time, OED only does this for MAMAC meters. (Obvius
pushes the data to OED so OED does not need to start that process.) If you have a MAMAC meter in your site
that you no longer want to collect data, then click the "Disable" button next to the green "Updates Enabled"
string. The string will change to "Updates Disabled" and go red. The button will become "Enable". Clicking
that button will reverse the process. (This is also visible to a regular user but they cannot change
setting.)</li>
<li>Meter Time Zone: This sets the time zone for this meter and overrides the <a href="adminPreferences.html">site
preferences</a> time zone value.
This is useful if some meters are not in the same time zone as the site default. See the <a href="time.html">time
help page</a> for further information.</li>
2 changes: 1 addition & 1 deletion help/v1.0.0/export.html
Original file line number Diff line number Diff line change
Expand Up @@ -97,7 +97,7 @@ <h3>Line graphics</h3>
href="./files/oedRawExport_line_July_15_2020_9_10_00_AM_to_September_24_2020_3_30_00_PM_Great Dorm 2nd Floor Electric.csv">Great
Dorm 2nd Floor Electric</a>
</p>
<p>The size of this CSV file scales with the number
<p id="exportSize">The size of this CSV file scales with the number
of meter points and can be large. To avoid accidental or inappropriate downloads of large files, OED does the
following:</p>
<ul>
Expand Down
Binary file added help/v1.0.0/images/adminMeterAreaUnitDropdown.png
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.

This file was deleted.

Loading

0 comments on commit a857ceb

Please sign in to comment.