Release 5.2

Compare
Choose a tag to compare
@hvxl hvxl released this 28 Dec 20:22
· 64 commits to master since this release
  • Handle Smart Power level changes while in monitor mode.
  • Add support for boilers that generate unsolicited Medium/High power.
  • Limit the validity of a CS command. A remotely set control setpoint expires after just over a minute. This is a safety feature to prevent runaway heating when the controlling program loses its connection, or crashes.
  • Change the default voltage reference to 1.458V (4), which translates to a line voltage that lies closer to the midway point between the high and low voltage levels defined by the Opentherm specification.
  • Change the voltage to detect a disconnected thermostat to 20.05V. The old value of 19.11V might give false positives due to component tolerances.
  • Pass on the response for MsgID 9 and MsgID 100 from the boiler (or a downstream gateway) if it is a Read-Ack or Write-Ack and the OTGW doesn't have any active override itself.