To use the Matek 1G3SE with IRC Tramp. You will need to enter the CLI command set vtx_frequency_group = FREQUENCYGROUP_1G3
. You must also make sure that the initial VTx settings in the configuration tab are in a valid range. They are:
vtx_band
1 or 2vtx_channel
between 1 and 8
Note: The frequencies required by the US version of the VTx are on vtx_band
2 (BAND B) only.
Power levels are:
1
25mW2
200mW3
800 mW
Band | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
---|---|---|---|---|---|---|---|---|
A | 1080 | 1120 | 1160 | 1200 | 1240 | 1280 | 1320 | 1360 |
B | 1080 | 1120 | 1160 | 1200 | 1258 | 1280 | 1320 | 1360 |
If you have problems getting SmartAudio working. There are a couple of CLI parameters you can try changing to see if they help.
-
There is a workaround for early AKK VTx modules. This is enabled by default. You could try disabling this setting
vtx_smartaudio_early_akk_workaround
to OFF. -
If you are using softserial, you can try using the alternate method by setting
vtx_smartaudio_alternate_softserial_method
to OFF. -
If you are using TBS Sixty9 VTX you may consider to set count of stop bits to 1, using
set vtx_smartaudio_stopbits = 1