This issue is to remove the parameter CD from Airflow.Multizone.EffectiveAirLeakageArea as it is not used in the model. This requires using BaseClasses.PowerLawResistance rather than Orifice as the base class.

@mwetter mwetter self-assigned this May 30, 2018
mwetter added a commit that referenced this issue Jun 15, 2018
mwetter added a commit that referenced this issue Jun 18, 2018
mwetter added a commit that referenced this issue Jun 19, 2018
V_flow is about the same, but the velocity changed due to the different reference area