Calibration for Kinect v2 in the main GUI doesn't work #11

Closed
matlabbe opened this issue May 2, 2015 · 1 comment
Closed

Calibration for Kinect v2 in the main GUI doesn't work #11

matlabbe opened this issue May 2, 2015 · 1 comment

Comments

@matlabbe
Copy link
Member

matlabbe commented May 2, 2015

A workaround for now, calibrate from the calibration tool:

$ rtabmap-calibration --driver 5 --stereo

Copy the generated files in a folder called "camera_info" in the RTAB-Map's working directory (default ~/Documents/RTAB-Map). Open RTAB-Map and by selecting the Freenect2 driver, the calibration should be loaded on start.

@matlabbe
Copy link
Member Author

matlabbe commented May 5, 2015

Fixed by 0d500ff and 679d9de