[Hardware Request]: Gen3-devices of the Shelly Plus 1 Mini Gen. 3 #927

Closed
2 tasks done
Khazaa opened this issue Jan 6, 2024 · 13 comments
Closed
2 tasks done

[Hardware Request]: Gen3-devices of the Shelly Plus 1 Mini Gen. 3 #927

Khazaa opened this issue Jan 6, 2024 · 13 comments
Assignees
Labels
fixed Issue fixed, please test hardware request Request to integrate new devices

Comments

@Khazaa
Copy link

Khazaa commented Jan 6, 2024

I'm sure that

  • This device is still unsupported in the current beta version of this adapter
  • There is no other (open) request for the same device type (used the search)

Shelly device

Shelly Plus 1 Mini Gen. 3

Further information

Hello,
I don't know how to look in the beta version. If this device is in the the beta, sorry!

I bought the Shelly and the adapter log says:
[MQTT] Client Close: (shelly1minig3 / shelly1minig3-84fce636ca58 / undefined) (false)
[MQTT] DO NOT CHANGE THE CLIENT-ID OF YOUR SHELLY DEVICES (see adapter documentation for details)
[MQTT] (Shelly?) device unknown, configuration for client with id "shelly1minig3-84fce636ca58" does not exist! Maybe this device is not supported in this adapter version.

I didn't change the client-id.

Here are some data from the Shelly:
Shelly Mini1G3 84FCE636CA58| 1.1.0| 8372d8c8|
Firmware-ID: 20231219-134003/1.1.0-g34b5d4f

If you need some more information, just ask :)

And thank you for your help!

Copy link

github-actions bot commented Jan 6, 2024

Thanks for reporting a new issue @Khazaa!

  1. Please make sure your topic is not covered in the documentation
  2. Ensure that you use the latest beta version (not the current stable version): 6.7.0
  3. Please attach all necessary log files (in debug mode!), screenshots and other information to reproduce this issue
  4. Search for the issue topic in other/closed issues to avoid duplicates!

Otherwise this issue will be closed.

@Khazaa
Copy link
Author

Khazaa commented Jan 6, 2024

[update] I found out, how to use the beta (6.7.0) und the device is still not usable with it.

@klein0r klein0r added the hardware request Request to integrate new devices label Jan 6, 2024
@HanSolo72
Copy link

You can close this case. I already opened it here: #915

@Khazaa
Copy link
Author

Khazaa commented Jan 19, 2024

Sure? My device is not the "PM" Version...

@HanSolo72
Copy link

Sorry, you're right. Was late last night.

BooosesThaSnipper added a commit to BooosesThaSnipper/ioBroker.shelly that referenced this issue Jan 28, 2024
@Joylancer
Copy link

i have removed "g3" from clientid in mqtt-settings, works as PMMINI
grafik

@garfield7791
Copy link

Just tested Joylancers comment. It really works if you remove "G3" from client ID. Thanks!

klein0r pushed a commit that referenced this issue Mar 18, 2024
* Add Humidity for DHT22 connected to Shelly Plus Addon

#738

* Revert "Add Humidity for DHT22 connected to Shelly Plus Addon"

This reverts commit da85a69.

* #936 - fix wrong description

* #915 / #927 - Add Gen3 Mini Devices:

#915 / #927 - Add Gen3 Mini Devices:
- #915
- #927

* Revert "#915 / #927 - Add Gen3 Mini Devices:"

This reverts commit ec72d89.

* Update shellytrv.js - nochange, just retrigger checks

---------

Co-authored-by: Martin M <mcm57@gmx.at>
@AceAutomation
Copy link

Hi - Can anyone tell me what to put in the MQTT payload and topic to activate the relay on a Shelly Plus 1 Mini Gen 3, I've tried almost everything, to no avail. I become crazy. It is connected to the broker.
For example, if MQTT prefix and Client ID is like the screenshot above.
Thanks

@SpeedyQ
Copy link

SpeedyQ commented Apr 5, 2024

Please find my yaml configuration below (to be used with mqtt and homeassistant) where you also see the payload I use to switch the mini on/off.
In the mini configuration I did not tick the setting ' RPC status notifications over MQTT', all other settings are similar as the screen dump above.

Shelly mini1 G3 bathroom

  • name: "Bathroom light"
    unique_id: "Bathroom_light"
    state_topic: "shellies/shelly1minig3-84fce63a3088/status/switch:0"
    command_topic: "shellies/shelly1minig3-84fce63a3088/rpc"
    availability_topic: "shellies/shelly1minig3-84fce63a3088/online"
    <<: &shelly_mini1_switch
    state_on: true
    state_off: false
    value_template: "{{ value_json['output'] }}"
    payload_on: '{"id": 1, "src": "homeassistant", "method": "Switch.Set", "params":{"id":0,"on":true}}'
    payload_off: '{"id": 1, "src": "homeassistant", "method": "Switch.Set", "params":{"id":0,"on":false}}'
    payload_available: "true"
    payload_not_available: "false"
    qos: 1
    retain: false

Also note that the settings below '<<: &shelly_mini1_switch' are generic and can be configured only once and you can reference these if you have more mini's.
Example:

Shelly mini1 G3 office

  • name: "Office light"
    unique_id: "Office_light"
    state_topic: "shellies/shelly1minig3-ecda3bc2f744/status/switch:0"
    command_topic: "shellies/shelly1minig3-ecda3bc2f744/rpc"
    availability_topic: "shellies/shelly1minig3-ecda3bc2f744/online"
    <<: *shelly_mini1_switch

@Pava1955
Copy link

Hi ho provato i comandi che hai scritto sopra per gestire accensione e spegniamento della caldai (mini1Gen3) purtroppo non riesco a farlo funzionare. di seguito quello che "vedo" con MQTT Explorer:

V shelly1minig3-84fce63ba33c**
V status
switch:0 = {"id":0,"source":"init", "output":false, "temperature":{"tC":57.7,"tF":135.9}}
ble = 0
cloud = {"connected":true}
input:0 = {"id":0,"state":false}
mqtt = {"connected":true}
script: 1 = {"id":1,"running":true, "mem_used":462,"mem_peak":1302,"mem_free":24738}
sys = {"mac":"84FCE63BA33C", "restart_required":false,"time":null, "unixtime":null,"uptime":2,"ram_size":259400,"ram_free":96416,"fs_size": 1048576,"fs_free":712704,"cfg_rev":13,"kvs_rev":3,"schedule_rev":0,"webhook_rev":0,"available_updates":0,"reset_reason":3}
wifi = {"sta_ip":"192.168.1.14","status":"got ip","ssid":"Vodafone-A41357753","rssi" :- 79}
ws = {"connected":false}
V events
rpc = {"src":"shelly1minig3-84fce63ba33c","dst":"shelly1minig3-84fce63ba33c/events","method":"NotifyStatus","params":{"ts": 1713278915.28,"cloud":{"connected":true}}}
online = true

e questo è il file yaml riferito allo switch:

  • name: "CaldaiaiSwitch"
    unique_id: "CaldaiaiSwitch"
    state_topic: "shelly1minig3-84fce63ba33c/status/switch:0"
    command_topic: "shelly1minig3-84fce63ba33c/events/rpc"
    availability_topic: "shelly1minig3-84fce63ba33c/online"

<<: &shelly_mini1_switch

state_on: "true"
state_off: "false"
value_template: "{{ value_json.output }}"
payload_on: '{"id": 1, "src": "homeassistant", "method": "Switch.Set", "params":{"id":0,"on":true}}'
payload_off: '{"id": 1, "src": "homeassistant", "method": "Switch.Set", "params":{"id":0,"on":false}}'
payload_available: "true"
payload_not_available: "false"
qos: 1
retain: false

dove sbaglio ??
Grazie a chi vorrà darmi una mano !

@SpeedyQ
Copy link

SpeedyQ commented Apr 16, 2024

Hi ho provato i comandi che hai scritto sopra per gestire accensione e spegniamento della caldai (mini1Gen3) purtroppo non riesco a farlo funzionare. di seguito quello che "vedo" con MQTT Explorer:

V shelly1minig3-84fce63ba33c**

V status
switch:0 = {"id":0,"source":"init", "output":false, "temperature":{"tC":57.7,"tF":135.9}}
ble = 0
cloud = {"connected":true}
input:0 = {"id":0,"state":false}
mqtt = {"connected":true}
script: 1 = {"id":1,"running":true, "mem_used":462,"mem_peak":1302,"mem_free":24738}
sys = {"mac":"84FCE63BA33C", "restart_required":false,"time":null, "unixtime":null,"uptime":2,"ram_size":259400,"ram_free":96416,"fs_size": 1048576,"fs_free":712704,"cfg_rev":13,"kvs_rev":3,"schedule_rev":0,"webhook_rev":0,"available_updates":0,"reset_reason":3}
wifi = {"sta_ip":"192.168.1.14","status":"got ip","ssid":"Vodafone-A41357753","rssi" :- 79}
ws = {"connected":false}
V events
rpc = {"src":"shelly1minig3-84fce63ba33c","dst":"shelly1minig3-84fce63ba33c/events","method":"NotifyStatus","params":{"ts": 1713278915.28,"cloud":{"connected":true}}}
online = true

e questo è il file yaml riferito allo switch:

* name: "CaldaiaiSwitch"
  unique_id: "CaldaiaiSwitch"
  state_topic: "shelly1minig3-84fce63ba33c/status/switch:0"
  command_topic: "shelly1minig3-84fce63ba33c/events/rpc"
  availability_topic: "shelly1minig3-84fce63ba33c/online"

<<: &shelly_mini1_switch

state_on: "true"

state_off: "false"
value_template: "{{ value_json.output }}"
payload_on: '{"id": 1, "src": "homeassistant", "method": "Switch.Set", "params":{"id":0,"on":true}}'
payload_off: '{"id": 1, "src": "homeassistant", "method": "Switch.Set", "params":{"id":0,"on":false}}'
payload_available: "true"
payload_not_available: "false"
qos: 1
retain: false

dove sbaglio ?? Grazie a chi vorrà darmi una mano !

I am not sure what your setup is, but it looks like you have cloud services enabled, so a lot of items shown in MQTT explorer is not what I see in my setup. To be clear, I am not using Shelly cloud. Instead I use everything locally; my MQTT server, Home Assistant and the Shelly. If I switch on my bathroom light shelly, it only displays few properties in MQTT explorer. See picture.
MQTTExplorer

@mcm1957
Copy link
Member

mcm1957 commented Apr 16, 2024

Please use ENGLISH or GERMAN language,

@AceAutomation

This comment was marked as off-topic.

@klein0r klein0r added the fixed Issue fixed, please test label Apr 29, 2024
@klein0r klein0r closed this as completed Apr 29, 2024