Fixed Master Mode PCB (connected GND pins) #127

Merged
merged 2 commits into from
Dec 13, 2019
Merged

Conversation

jrsteensen
Copy link
Owner

Connected trace to rear ground plane.

Description

Added 24mil trace between pins 5&6, connecting trace to ground plane. Require new manufacturing file generation.

Addresses #126

Type of change

Please delete options that are not relevant.

  • Change ECAD (fixed issue with existing PCB)

Checklist: (Delete non-relevant sections)

PCB/ECAD:

  • Requirements definition
  • Schematic completed
  • PCB routed
  • PCB constrained by physical footprint limitations
  • PCB critical component location requirements met
  • Schematic/PCB reviewed
  • BOM generated
  • Gerbers generated
  • MCAD generated

Connected trace to rear ground plane.
@jrsteensen jrsteensen added Type: Bug/Obsolesce Something isn't working/Part no longer available for sale Category: ECAD Electrical CAD/PCB HW Design Priority: High labels Dec 12, 2019
@jrsteensen jrsteensen added this to the 1) Upper Instrument Panel milestone Dec 12, 2019
@jrsteensen jrsteensen self-assigned this Dec 12, 2019
@jrsteensen jrsteensen added this to In progress in End Item: Upper Instrument Panel HW via automation Dec 12, 2019
@amanuense
Copy link
Collaborator

amanuense commented Dec 12, 2019 via email

@jrsteensen
Copy link
Owner Author

Odd I'll take a look. I suspect it is just the ground plane not attached to ground

On Thu, Dec 12, 2019, 08:16 John Steensen @.***> wrote: Connected trace to rear ground plane. Description Added 24mil trace between pins 5&6, connecting trace to ground plane. Require new manufacturing file generation. Addresses #126 <#126> Type of change Please delete options that are not relevant. - Change ECAD (fixed issue with existing PCB) Checklist: (Delete non-relevant sections) PCB/ECAD: - Requirements definition - Schematic completed - PCB routed - PCB constrained by physical footprint limitations - PCB critical component location requirements met - Schematic/PCB reviewed - BOM generated - Gerbers generated - MCAD generated ------------------------------ You can view, comment on, or merge this pull request online at: #127 Commit Summary - Added 24mil trace between pins 5 & 6 File Changes - M ECAD/PCBs for Sim/Master Mode Pushbutton/MasterModePushbutton.kicad_pcb https://github.com/jrsteensen/OpenHornet/pull/127/files#diff-0 (1896) - M ECAD/PCBs for Sim/Master Mode Pushbutton/MasterModePushbutton.kicad_pcb-bak https://github.com/jrsteensen/OpenHornet/pull/127/files#diff-1 (1783) Patch Links: - https://github.com/jrsteensen/OpenHornet/pull/127.patch - https://github.com/jrsteensen/OpenHornet/pull/127.diff — You are receiving this because your review was requested. Reply to this email directly, view it on GitHub <#127?email_source=notifications&email_token=AC7IBPIMHFDXQIODTCVKWRTQYJPT7A5CNFSM4J2BAMY2YY3PNVWWK3TUL52HS4DFUVEXG43VMWVGG33NNVSW45C7NFSM4IADEMNQ>, or unsubscribe https://github.com/notifications/unsubscribe-auth/AC7IBPMPH5VGNNVQ6JUKAX3QYJPT7ANCNFSM4J2BAMYQ .

Already fixed, that was the issue. Need this pull request reviewed, merged and manufacturing files generated.

@amanuense
Copy link
Collaborator

amanuense commented Dec 13, 2019 via email

@amanuense
Copy link
Collaborator

@jrsteensen the fix was done incorrectly. For future reference, the correct way to fix these issues is to fix them in schematic (already done)., then on pcbnew there is a button to update PCB from schematic.

I will generate the gerber files no other change is required.

@balzreber @jrsteensen please review once you see my commit

1 similar comment
@amanuense
Copy link
Collaborator

@jrsteensen the fix was done incorrectly. For future reference, the correct way to fix these issues is to fix them in schematic (already done)., then on pcbnew there is a button to update PCB from schematic.

I will generate the gerber files no other change is required.

@balzreber @jrsteensen please review once you see my commit

published updated gerber files.
removed bak file
@jrsteensen jrsteensen merged commit 17bfa79 into master Dec 13, 2019
End Item: Upper Instrument Panel HW automation moved this from In progress to Done Dec 13, 2019
@jrsteensen jrsteensen deleted the fix_master_mode branch December 13, 2019 18:05