Notifications
You must be signed in to change notification settings - Fork 0
/
phew Check WF v2.3.py
117 lines (100 loc) · 6.29 KB
/
phew Check WF v2.3.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
# 4 Nov V 2.3 - added up and down to the messages -
# 31 Oct 2020 - Changed range for EC 750-950
# V 2.2 added changed ranges for pH 5.8-6.2 and EC 550-850
# V 2.1 added waterflow volume check before dosing chemicals
## Edit below to set desired ranges for pH and electrical conductivity ###
# Low value for water flow in liters per minute
range_wf_low = 0.2
# Desired range for electrical conductivity
range_ec_high = 950
range_ec_low = 750
# Desired range for pH
range_ph_high = 6.2
range_ph_low = 5.8
# pH range that will immediately cause a pH correction
range_ph_high_danger = 7.0
range_ph_low_danger = 5.0
### Edit below to set the IDs for Conditions and Actions ###
condition_id_measurement_ph_id = "{18a811f0}" # Condition: measurement, last, pH Input
condition_id_measurement_ec_id = "{5d050302}" # Condition: measurement, last, EC Input
condition_id_measurement_wf_id = "{54cb18df}" # Condition: measurement, last, wf Input
action_id_pump_1_acid = "{4262eedc}" # Action: Pump 1 (Acid)
action_id_pump_2_base = "{5d400167}" # Action: Pump 2 (Base)
action_id_pump_3_nutrient_a = "{54a0ac22}" # Action: Pump 3 (Nutrient A)
action_id_pump_4_nutrient_b = "{a1c160da}" # Action: Pump 4 (Nutrient B)
action_id_email_notification = "{3332c9bb}" # Action: Email Notification
### DO NOT EDIT BELOW THIS LINE UNLESS YOU KNOW WHAT YOU ARE DOING ###
import time
if 'notify_ec' not in self.variables: # Initiate EC notification timer
self.variables['notify_ec'] = 0
if 'notify_ph' not in self.variables: # Initiate pH notification timer
self.variables['notify_ph'] = 0
if 'notify_none' not in self.variables: # Initiate None measurement notification timer
self.variables['notify_none'] = 0
if 'notify_wf' not in self.variables: # Initiate wf (water flow) measurement notification timer
self.variables['notify_wf'] = 0
measure_ec = self.condition(condition_id_measurement_ec_id)
measure_ph = self.condition(condition_id_measurement_ph_id)
measure_wf = self.condition(condition_id_measurement_wf_id) #id for water flow
self.message = ""
# self.logger.debug("Conditional check. EC: {}, pH: {}, wf: {}".format(measure_ec, measure_ph, measure_wf))
self.logger.debug("Conditional check. EC: {}, pH: {}, wf: {}".format(measure_ec, measure_ph, measure_wf))
if None in [measure_ec, measure_ph, measure_wf]:
if measure_ec is None:
self.message += "\nWarning: No EC Measurement! Check sensor!"
if measure_ph is None:
self.message += "\nWarning: No pH Measurement! Check sensor!"
if measure_wf is None:
self.message += "\nWarning: No Measure WF"
if self.variables['notify_none'] < time.time(): # Only notify every 12 hours
self.variables['notify_none'] = time.time() + 21600 # 6 hours
self.run_action(action_id_email_notification, message=self.message) # Email alert
self.logger.error(self.message)
return
if measure_wf < range_wf_low: # if water flow is less than .2 liters per hour then skip the remaining steps.
msg = "Hydroponics water flow is dangerously low at {} liters per minute. Should be > 0.6. pH is: {}. EC is: {}. Check the water flow. No other chemical dispensing will occur till water flow is at least 0.2 liters per hour.".format(measure_wf, measure_ph, measure_ec)
self.logger.info(msg)
self.message += msg
if self.variables['notify_wf'] < time.time(): # Only notify every 4 hours
self.variables['notify_wf'] = time.time() + 1440 # 4 hours
self.run_action(action_id_email_notification, message=self.message) # Email alert
# next check if pH is dangerously low or high, and adjust if it is
elif measure_ph < range_ph_low_danger: # pH dangerously low, add base (pH up)
msg = "Hydroponics pH is dangerously low: {}. Should be > {}. Dispensing base (pH up)".format(measure_ph, range_ph_low_danger)
self.logger.info(msg)
self.message += msg
self.run_action(action_id_pump_2_base) # Dispense base (pH up)
if self.variables['notify_ph'] < time.time(): # Only notify every 12 hours
self.variables['notify_ph'] = time.time() + 43200 # 12 hours
self.run_action(action_id_email_notification, message=self.message) # Email alert
elif measure_ph > range_ph_high_danger: # pH dangerously high, add acid (pH down)
msg = "Hydroponics pH is dangerously high: {}. Should be < {}. Dispensing acid (pH down)".format(measure_ph, range_ph_high_danger)
self.logger.info(msg)
self.message += msg
self.run_action(action_id_pump_1_acid) # Dispense acid (pH down)
if self.variables['notify_ph'] < time.time(): # Only notify every 12 hours
self.variables['notify_ph'] = time.time() + 43200 # 12 hours
self.run_action(action_id_email_notification, message=self.message) # Email alert
# If pH isn't dangerously low or high, check if EC is within range
elif measure_ec < range_ec_low: # EC too low, add nutrient
self.logger.info("EC: {}. Should be > {}. Dispensing Nutrient A and B".format(measure_ec, range_ec_low))
self.run_action(action_id_pump_3_nutrient_a) # Dispense nutrient A
self.run_action(action_id_pump_4_nutrient_b) # Dispense nutrient B
elif measure_ec > range_ec_high: # EC too high, add water
msg = "Hydroponics EC: {}. Should be < {}. Need to add water to dilute!".format(measure_ec, range_ec_high)
self.logger.info(msg)
if self.variables['notify_ec'] < time.time(): # Only notify every 12 hours
self.variables['notify_ec'] = time.time() + 43200 # 12 hours
self.message += msg
self.run_action(action_id_email_notification, message=self.message) # Email alert
# If EC is in range, make sure pH is within range
elif measure_ph < range_ph_low: # pH too low, add base (pH up)
self.logger.info("EC is okay at {}. pH is {}. It should be > {}. Dispensing base (pH up)".format(measure_ec, measure_ph, range_ph_low))
self.run_action(action_id_pump_2_base) # Dispense base (pH up)
elif measure_ph > range_ph_high: # pH too high, add acid (pH down)
self.logger.info("EC is okay at {}. pH is {}. Should be < {}. Dispensing acid (pH down)".format(measure_ec, measure_ph, range_ph_high))
self.run_action(action_id_pump_1_acid) # Dispense acid (pH down)
# else: # EC and PH are okay
# self.logger.info("EC and pH are okay")
# self.message = "EC and pH are okay"
# self.run_action(action_id_email_notification, message=self.message) # Email alert