HB Window Opening.py
142 lines (129 loc) · 7.07 KB
/
HB Window Opening.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
# Honeybee: A Plugin for Environmental Analysis (GPL)
# This file is part of Honeybee.
#
# Copyright (c) 2024, Ladybug Tools.
# You should have received a copy of the GNU Affero General Public License
# along with Honeybee; If not, see <http://www.gnu.org/licenses/>.
#
# @license AGPL-3.0-or-later <https://spdx.org/licenses/AGPL-3.0-or-later>
"""
Define the window opening properties for all operable apertures of a Room.
_
By default, the properties assigned by this component are translated into simple
ZoneVentilation objects in the resulting IIDF, which can approximate airflow
from both single-sided bouyancy-driven ventilation as well as wind-driven cross
ventilation. Bouyancy-driven flow can happen for essentially all openings while
wind-driven flow can only happen when there are pressure differences across
windows on opposite sides of a Room.
_
Simple ZoneVentilation is computed using the following formulas:
_
VentilationWind = WindCoefficient * OpeningArea * Schedule * WindSpeed
VentilationStack = StackDischargeCoefficient * OpeningArea * ScheduleValue *
SQRT(2 * GravityAccelration * HeightNPL * (|(TempZone - TempOutdoors)| / TempZone))
TotalVentilation = SQRT((VentilationWind)^2 + (VentilationStack)^2)
_
Note that the (OpeningArea) term is derived from the _fract_area_oper_ and the area
of each aperture while the (HeightNPL) term is derived from the _fract_height_oper_
and the height of each aperture. The "NPL" stands for "Neutral Plane" and the
whole term represents the height from midpoint of lower opening to the neutral
pressure level of the window (computed as 1/4 of the height of each Aperture in
the translation from honeybee to IDF).
_
More complex airflow phenomena can be modeled by using this component in conjunction
with with the Airflow Network (AFN) component. Note that the window opening
properties assigned by this component are still relevant for such AFN simulations.
-
Args:
_rooms: Honeybee Room objects to which window ventilation opening properties
will be assigned. Note that this component only assigns such properties
to operable Apertures on the rooms. If the is_operable property
of any of a room's apertures is not True, no opening properties
will be assigned.
_vent_cntrl: A Ventilation Control object from the "HB Ventilation Control"
component, which dictates the opening behaviour of the Room's apertures.
_fract_area_oper_: A number between 0.0 and 1.0 for the fraction of the
window area that is operable. (Default: 0.5, typical of sliding windows).
_fract_height_oper_: A number between 0.0 and 1.0 for the fraction
of the distance from the bottom of the window to the top that is
operable. (Default: 1.0, typical of windows that slide horizontally).
_discharge_coeff_: A number between 0.0 and 1.0 that will be multipled
by the area of the window in the stack (buoyancy-driven) part of the
equation to account for additional friction from window geometry,
insect screens, etc. (Default: 0.45, for unobstructed windows with
insect screens). This value should be lowered if windows are of an
awning or casement type and not allowed to fully open. Some common
values for this coefficient include the following.
-
* 0.0 - Completely discount stack ventilation from the calculation.
* 0.45 - For unobstructed windows with an insect screen.
* 0.65 - For unobstructed windows with NO insect screen.
_wind_cross_vent_: Boolean to indicate if there is an opening of roughly
equal area on the opposite side of the Room such that wind-driven
cross ventilation will be induced. If False, the assumption is that
the operable area is primarily on one side of the Room and there is
no wind-driven ventilation. If None, the normal vectors of the
operable aperturs of the input _rooms will be analyzed. If window
normals of a given room are found to have an angle difference greater
than 90 degrees, cross ventilation will be set to True. Otherwise,
it will be False.
Returns:
rooms: The input Honeybee Rooms with their window-opening properties edited.
"""
ghenv.Component.Name = 'HB Window Opening'
ghenv.Component.NickName = 'WindowOpen'
ghenv.Component.Message = '1.8.0'
ghenv.Component.Category = 'HB-Energy'
ghenv.Component.SubCategory = '3 :: Loads'
ghenv.Component.AdditionalHelpFromDocStrings = '4'
try:
from honeybee_energy.ventcool.opening import VentilationOpening
except ImportError as e:
raise ImportError('\nFailed to import honeybee_energy:\n\t{}'.format(e))
try:
from ladybug_rhino.grasshopper import all_required_inputs, give_warning, \
longest_list
except ImportError as e:
raise ImportError('\nFailed to import ladybug_rhino:\n\t{}'.format(e))
if all_required_inputs(ghenv.Component):
# loop through the rooms and assign the objects
op_count = 0
rooms = []
for i, room_init in enumerate(_rooms):
room = room_init.duplicate() # duplicate to avoid editing the input
# assign the ventilation control for the windows
room.properties.energy.window_vent_control = longest_list(_vent_cntrl, i)
# create the base ventilation opening
f_area = 0.5 if len(_fract_area_oper_) == 0 else longest_list(_fract_area_oper_, i)
f_height = 1.0 if len(_fract_height_oper_) == 0 else longest_list(_fract_height_oper_, i)
discharge = 0.45 if len(_discharge_coeff_) == 0 else longest_list(_discharge_coeff_, i)
vent_open = VentilationOpening(f_area, f_height, discharge)
# assign the cross ventilation
cross_vent = longest_list(_wind_cross_vent_, i) if \
len(_wind_cross_vent_) != 0 else None
if cross_vent is None:
# analyze normals of room's apertures to test if cross vent is possible
orient_angles = []
for face in room.faces:
for ap in face.apertures:
if ap.is_operable:
try:
orient_angles.append(ap.horizontal_orientation())
except ZeroDivisionError:
orient_angles.append(0)
if len(orient_angles) != 0:
orient_angles.sort()
vent_open.wind_cross_vent = \
True if orient_angles[-1] - orient_angles[0] >= 90 else False
else:
vent_open.wind_cross_vent = False
else:
vent_open.wind_cross_vent = cross_vent
vent_aps = room.properties.energy.assign_ventilation_opening(vent_open)
rooms.append(room)
op_count += len(vent_aps)
# give a warning if no operable windows were found among the connected rooms
if op_count == 0:
give_warning(
ghenv.Component, 'No operable Apertures were found among the connected _rooms.\n'
'Make sure that you have set the is_operable property of Apertures to True.')