Add initial unit tests and automated CI
Browse files Browse the repository at this point in the history
  • Loading branch information
odow committed Jan 21, 2024
1 parent 9853173 commit 42c2200
Show file tree
Hide file tree
Showing 8 changed files with 724 additions and 62 deletions.
29 changes: 29 additions & 0 deletions .github/workflows/ci.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,29 @@
name: CI
on:
push:
branches:
- main
pull_request:
types: [opened, synchronize, reopened]
jobs:
test:
name: ${{ matrix.version }} - ${{ matrix.os }} - ${{ matrix.arch }} - ${{ github.event_name }}
runs-on: ${{ matrix.os }}
strategy:
fail-fast: false
matrix:
version: ['1']
os: [ubuntu-latest]
arch: [x64]
steps:
- uses: actions/checkout@v3
- uses: julia-actions/setup-julia@v1
with:
version: ${{ matrix.version }}
arch: ${{ matrix.arch }}
- name: install
shell: julia --color=yes --project=. {0}
run: |
using Pkg
Pkg.instantiate()
- run: julia --color=yes --project=. test/runtests.jl
214 changes: 214 additions & 0 deletions data/pglib_opf_case14_ieee.m
Original file line number Diff line number Diff line change
@@ -0,0 +1,214 @@
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%%% %%%%%
%%%% IEEE PES Power Grid Library - Optimal Power Flow - v21.07 %%%%%
%%%% (https://github.com/power-grid-lib/pglib-opf) %%%%%
%%%% Benchmark Group - Typical Operations %%%%%
%%%% 29 - July - 2021 %%%%%
%%%% %%%%%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%
% Power flow data for IEEE 14 bus test case.
% This data was converted from IEEE Common Data Format
% (ieee14cdf.txt) on 20-Sep-2004 by cdf2matp, rev. 1.11
%
% Converted from IEEE CDF file from:
% http://www.ee.washington.edu/research/pstca/
%
% Copyright (c) 1999 by Richard D. Christie, University of Washington
% Electrical Engineering Licensed under the Creative Commons Attribution 4.0
% International license, http://creativecommons.org/licenses/by/4.0/
%
% CDF Header:
% 08/19/93 UW ARCHIVE 100.0 1962 W IEEE 14 Bus Test Case
%
function mpc = pglib_opf_case14_ieee
mpc.version = '2';
mpc.baseMVA = 100.0;

%% bus data
% bus_i type Pd Qd Gs Bs area Vm Va baseKV zone Vmax Vmin
mpc.bus = [
1 3 0.0 0.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
2 2 21.7 12.7 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
3 2 94.2 19.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
4 1 47.8 -3.9 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
5 1 7.6 1.6 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
6 2 11.2 7.5 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
7 1 0.0 0.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
8 2 0.0 0.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
9 1 29.5 16.6 0.0 19.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
10 1 9.0 5.8 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
11 1 3.5 1.8 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
12 1 6.1 1.6 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
13 1 13.5 5.8 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
14 1 14.9 5.0 0.0 0.0 1 1.00000 0.00000 1.0 1 1.06000 0.94000;
];

%% generator data
% bus Pg Qg Qmax Qmin Vg mBase status Pmax Pmin
mpc.gen = [
1 170.0 5.0 10.0 0.0 1.0 100.0 1 340 0.0; % NG
2 29.5 0.0 30.0 -30.0 1.0 100.0 1 59 0.0; % NG
3 0.0 20.0 40.0 0.0 1.0 100.0 1 0 0.0; % SYNC
6 0.0 9.0 24.0 -6.0 1.0 100.0 1 0 0.0; % SYNC
8 0.0 9.0 24.0 -6.0 1.0 100.0 1 0 0.0; % SYNC
];

%% generator cost data
% 2 startup shutdown n c(n-1) ... c0
mpc.gencost = [
2 0.0 0.0 3 0.000000 7.920951 0.000000; % NG
2 0.0 0.0 3 0.000000 23.269494 0.000000; % NG
2 0.0 0.0 3 0.000000 0.000000 0.000000; % SYNC
2 0.0 0.0 3 0.000000 0.000000 0.000000; % SYNC
2 0.0 0.0 3 0.000000 0.000000 0.000000; % SYNC
];

%% branch data
% fbus tbus r x b rateA rateB rateC ratio angle status angmin angmax
mpc.branch = [
1 2 0.01938 0.05917 0.0528 472 472 472 0.0 0.0 1 -30.0 30.0;
1 5 0.05403 0.22304 0.0492 128 128 128 0.0 0.0 1 -30.0 30.0;
2 3 0.04699 0.19797 0.0438 145 145 145 0.0 0.0 1 -30.0 30.0;
2 4 0.05811 0.17632 0.034 158 158 158 0.0 0.0 1 -30.0 30.0;
2 5 0.05695 0.17388 0.0346 161 161 161 0.0 0.0 1 -30.0 30.0;
3 4 0.06701 0.17103 0.0128 160 160 160 0.0 0.0 1 -30.0 30.0;
4 5 0.01335 0.04211 0.0 664 664 664 0.0 0.0 1 -30.0 30.0;
4 7 0.0 0.20912 0.0 141 141 141 0.978 0.0 1 -30.0 30.0;
4 9 0.0 0.55618 0.0 53 53 53 0.969 0.0 1 -30.0 30.0;
5 6 0.0 0.25202 0.0 117 117 117 0.932 0.0 1 -30.0 30.0;
6 11 0.09498 0.1989 0.0 134 134 134 0.0 0.0 1 -30.0 30.0;
6 12 0.12291 0.25581 0.0 104 104 104 0.0 0.0 1 -30.0 30.0;
6 13 0.06615 0.13027 0.0 201 201 201 0.0 0.0 1 -30.0 30.0;
7 8 0.0 0.17615 0.0 167 167 167 0.0 0.0 1 -30.0 30.0;
7 9 0.0 0.11001 0.0 267 267 267 0.0 0.0 1 -30.0 30.0;
9 10 0.03181 0.0845 0.0 325 325 325 0.0 0.0 1 -30.0 30.0;
9 14 0.12711 0.27038 0.0 99 99 99 0.0 0.0 1 -30.0 30.0;
10 11 0.08205 0.19207 0.0 141 141 141 0.0 0.0 1 -30.0 30.0;
12 13 0.22092 0.19988 0.0 99 99 99 0.0 0.0 1 -30.0 30.0;
13 14 0.17093 0.34802 0.0 76 76 76 0.0 0.0 1 -30.0 30.0;
];

% INFO : === Translation Options ===
% INFO : Phase Angle Bound: 30.0 (deg.)
% INFO : Line Capacity Model: stat
% INFO : Gen Active Capacity Model: stat
% INFO : Gen Reactive Capacity Model: am50ag
% INFO : Gen Active Cost Model: stat
% INFO : Setting Flat Start
% INFO : Line Capacity PAB: 15.0 (deg.)
% INFO :
% INFO : === Generator Classification Notes ===
% INFO : SYNC 3 - 0.00
% INFO : NG 2 - 100.00
% INFO :
% INFO : === Generator Active Capacity Stat Model Notes ===
% INFO : Gen at bus 1 - NG : Pg=232.4, Pmax=332.4 -> Pmax=340 samples: 20
% INFO : Gen at bus 2 - NG : Pg=40.0, Pmax=140.0 -> Pmax=59 samples: 6
% INFO : Gen at bus 3 - SYNC : Pg=0.0, Pmax=100.0 -> Pmax=0 samples: 0
% INFO : Gen at bus 6 - SYNC : Pg=0.0, Pmax=100.0 -> Pmax=0 samples: 0
% INFO : Gen at bus 8 - SYNC : Pg=0.0, Pmax=100.0 -> Pmax=0 samples: 0
% INFO :
% INFO : === Generator Reactive Capacity Atmost Max 50 Percent Active Model Notes ===
% INFO : Gen at bus 2 - NG : Pmax 59.0, Qmin -40.0, Qmax 50.0 -> Qmin -30.0, Qmax 30.0
% INFO :
% INFO : === Generator Active Cost Stat Model Notes ===
% INFO : Updated Generator Cost: NG - 0.0 20.0 0.0430293 -> 0 7.92095063323 0
% INFO : Updated Generator Cost: NG - 0.0 20.0 0.25 -> 0 23.2694943686 0
% INFO : Updated Generator Cost: SYNC - 0.0 40.0 0.01 -> 0 0.0 0
% INFO : Updated Generator Cost: SYNC - 0.0 40.0 0.01 -> 0 0.0 0
% INFO : Updated Generator Cost: SYNC - 0.0 40.0 0.01 -> 0 0.0 0
% INFO :
% INFO : === Generator Bounds Update Notes ===
% INFO :
% INFO : === Base KV Replacement Notes ===
% WARNING : Bus 1 : basekv changed 0.0 => 1.0
% WARNING : Bus 2 : basekv changed 0.0 => 1.0
% WARNING : Bus 3 : basekv changed 0.0 => 1.0
% WARNING : Bus 4 : basekv changed 0.0 => 1.0
% WARNING : Bus 5 : basekv changed 0.0 => 1.0
% WARNING : Bus 6 : basekv changed 0.0 => 1.0
% WARNING : Bus 7 : basekv changed 0.0 => 1.0
% WARNING : Bus 8 : basekv changed 0.0 => 1.0
% WARNING : Bus 9 : basekv changed 0.0 => 1.0
% WARNING : Bus 10 : basekv changed 0.0 => 1.0
% WARNING : Bus 11 : basekv changed 0.0 => 1.0
% WARNING : Bus 12 : basekv changed 0.0 => 1.0
% WARNING : Bus 13 : basekv changed 0.0 => 1.0
% WARNING : Bus 14 : basekv changed 0.0 => 1.0
% INFO :
% INFO : === Transformer Setting Replacement Notes ===
% INFO :
% INFO : === Line Capacity Stat Model Notes ===
% WARNING : Missing data for branch flow stat model on line 1-2 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.01938 x=0.05917
% INFO : Updated Thermal Rating: on line 1-2 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 472
% WARNING : Missing data for branch flow stat model on line 1-5 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.05403 x=0.22304
% INFO : Updated Thermal Rating: on line 1-5 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 128
% WARNING : Missing data for branch flow stat model on line 2-3 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.04699 x=0.19797
% INFO : Updated Thermal Rating: on line 2-3 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 145
% WARNING : Missing data for branch flow stat model on line 2-4 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.05811 x=0.17632
% INFO : Updated Thermal Rating: on line 2-4 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 158
% WARNING : Missing data for branch flow stat model on line 2-5 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.05695 x=0.17388
% INFO : Updated Thermal Rating: on line 2-5 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 161
% WARNING : Missing data for branch flow stat model on line 3-4 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.06701 x=0.17103
% INFO : Updated Thermal Rating: on line 3-4 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 160
% WARNING : Missing data for branch flow stat model on line 4-5 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.01335 x=0.04211
% INFO : Updated Thermal Rating: on line 4-5 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 664
% WARNING : Missing data for branch flow stat model on line 4-7 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.20912
% INFO : Updated Thermal Rating: on transformer 4-7 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 141
% WARNING : Missing data for branch flow stat model on line 4-9 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.55618
% INFO : Updated Thermal Rating: on transformer 4-9 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 53
% WARNING : Missing data for branch flow stat model on line 5-6 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.25202
% INFO : Updated Thermal Rating: on transformer 5-6 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 117
% WARNING : Missing data for branch flow stat model on line 6-11 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.09498 x=0.1989
% INFO : Updated Thermal Rating: on line 6-11 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 134
% WARNING : Missing data for branch flow stat model on line 6-12 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.12291 x=0.25581
% INFO : Updated Thermal Rating: on line 6-12 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 104
% WARNING : Missing data for branch flow stat model on line 6-13 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.06615 x=0.13027
% INFO : Updated Thermal Rating: on line 6-13 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 201
% WARNING : Missing data for branch flow stat model on line 7-8 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.17615
% INFO : Updated Thermal Rating: on line 7-8 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 167
% WARNING : Missing data for branch flow stat model on line 7-9 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.0 x=0.11001
% INFO : Updated Thermal Rating: on line 7-9 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 267
% WARNING : Missing data for branch flow stat model on line 9-10 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.03181 x=0.0845
% INFO : Updated Thermal Rating: on line 9-10 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 325
% WARNING : Missing data for branch flow stat model on line 9-14 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.12711 x=0.27038
% INFO : Updated Thermal Rating: on line 9-14 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 99
% WARNING : Missing data for branch flow stat model on line 10-11 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.08205 x=0.19207
% INFO : Updated Thermal Rating: on line 10-11 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 141
% WARNING : Missing data for branch flow stat model on line 12-13 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.22092 x=0.19988
% INFO : Updated Thermal Rating: on line 12-13 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 99
% WARNING : Missing data for branch flow stat model on line 13-14 using max current model : from_basekv=1.0 to_basekv=1.0 r=0.17093 x=0.34802
% INFO : Updated Thermal Rating: on line 13-14 : Rate A, Rate B, Rate C , 9900.0, 0.0, 0.0 -> 76
% INFO :
% INFO : === Line Capacity Monotonicity Notes ===
% INFO :
% INFO : === Voltage Setpoint Replacement Notes ===
% INFO : Bus 1 : V=1.06, theta=0.0 -> V=1.0, theta=0.0
% INFO : Bus 2 : V=1.045, theta=-4.98 -> V=1.0, theta=0.0
% INFO : Bus 3 : V=1.01, theta=-12.72 -> V=1.0, theta=0.0
% INFO : Bus 4 : V=1.019, theta=-10.33 -> V=1.0, theta=0.0
% INFO : Bus 5 : V=1.02, theta=-8.78 -> V=1.0, theta=0.0
% INFO : Bus 6 : V=1.07, theta=-14.22 -> V=1.0, theta=0.0
% INFO : Bus 7 : V=1.062, theta=-13.37 -> V=1.0, theta=0.0
% INFO : Bus 8 : V=1.09, theta=-13.36 -> V=1.0, theta=0.0
% INFO : Bus 9 : V=1.056, theta=-14.94 -> V=1.0, theta=0.0
% INFO : Bus 10 : V=1.051, theta=-15.1 -> V=1.0, theta=0.0
% INFO : Bus 11 : V=1.057, theta=-14.79 -> V=1.0, theta=0.0
% INFO : Bus 12 : V=1.055, theta=-15.07 -> V=1.0, theta=0.0
% INFO : Bus 13 : V=1.05, theta=-15.16 -> V=1.0, theta=0.0
% INFO : Bus 14 : V=1.036, theta=-16.04 -> V=1.0, theta=0.0
% INFO :
% INFO : === Generator Setpoint Replacement Notes ===
% INFO : Gen at bus 1 : Pg=232.4, Qg=-16.9 -> Pg=170.0, Qg=5.0
% INFO : Gen at bus 1 : Vg=1.06 -> Vg=1.0
% INFO : Gen at bus 2 : Pg=40.0, Qg=42.4 -> Pg=29.5, Qg=0.0
% INFO : Gen at bus 2 : Vg=1.045 -> Vg=1.0
% INFO : Gen at bus 3 : Pg=0.0, Qg=23.4 -> Pg=0.0, Qg=20.0
% INFO : Gen at bus 3 : Vg=1.01 -> Vg=1.0
% INFO : Gen at bus 6 : Pg=0.0, Qg=12.2 -> Pg=0.0, Qg=9.0
% INFO : Gen at bus 6 : Vg=1.07 -> Vg=1.0
% INFO : Gen at bus 8 : Pg=0.0, Qg=17.4 -> Pg=0.0, Qg=9.0
% INFO : Gen at bus 8 : Vg=1.09 -> Vg=1.0
% INFO :
% INFO : === Writing Matpower Case File Notes ===