Add temp polling for IBM Flexsystem switches #894

Merged
merged 3 commits into from May 3, 2015

Projects

None yet

4 participants

@Rosiak
Contributor
Rosiak commented May 1, 2015
  • Able to poll temps from IBM Flexsystem switches
  • Convert temp response to digit
@Rosiak Rosiak Add temp polling for IBM Flexsystem switches
- Able to poll temps from IBM Flexsystem switches
- Convert temp response to digit
94381f9
@paulgear
Member
paulgear commented May 1, 2015

One Scrutinizer issue that would be worth fixing: "The expression $check_oids of type false|string is loosely compared to true; this is ambiguous if the string can be empty. You might want to explicitly use !== false instead. "

@Rosiak Rosiak Update ibmnos.inc.php
- Updated to fit suggestions from scrut
92b9865
@Rosiak
Contributor
Rosiak commented May 2, 2015

Updated! Lafwood is testing the polling convert change, he'll merge when he's done testing.

@f0o f0o assigned f0o and laf and unassigned f0o May 3, 2015
@Rosiak Rosiak Update functions.inc.php
- Add extra safety check
b124c28
@laf laf merged commit fa06134 into librenms:master May 3, 2015
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment