There are a few errors in devices/goodcell_ev_charger.yaml configuration:
Sensors Voltage L2 and Voltage L3 are missing parameter mapping: - scale: 10
Sensors of class: energy should not be 'measurement' but 'total_increasing' for aggregate (integrative) values.
I attach a corrected yaml file. goodcell_ev_charger.zip
The text was updated successfully, but these errors were encountered:
Goodcell EV charger: correct scale and state class of some sensors.
a8396b9
- Voltages L2 and L3 should be scaled like L1 - energy sensor requires state class of total_increasing, not measurement Issue #1808